SUZ-SM60VA.TH
Refrigerant pipe ø 15.88
(with heat insulator)
Flared connection
Flared connection
Refrigerant pipe ø 6.35
(with heat insulator)
OCH779
4-way valve
Strainer
#50
Stop valve
(with service port)
Strainer
#100
Compressor
Capillary tube
ø3.0×ø2.0×200(×6)
Strainer
#100
Muffler
Stop valve
Capillary tube
ø 4.0 ×ø 2.4 × 100
19
Muffler
Outdoor
Defrost
heat
thermistor
exchanger
RT61
Discharge
temperature
thermistor
RT62
Outdoor heat
exchanger
temperature
thermistor
Distributer
RT68
LEV
Strainer
R.V. coil
#100
heating ON
cooling OFF
Refrigerant flow in cooling
Refrigerant flow in heating
Unit: mm
Ambient
temperature
thermistor
RT65