Autolist; Pip Display: Size And Position; Changing Positions And Colors Of Titles - JVC SW-D8000U Instruction Manual

Table of Contents

Advertisement

SW-D8000U, 16CH. COLOR VIDEO MULTIPLEXER
SEQUENCE
Press
Resolution of Full-screen displays:
The operator can switch the resolution of digital full-screen displays from 'frame' displays to
'field' displays. The lower resolution 'field' displays can result in less 'flickering' on some high
contrast camera scenes. Frame resolution is fully interlaced and provides higher resolution.
See FIELD/FRAME SETUP in the OPERATORS menu.
Note:
This is a global system setting and all camera displays will be changed.
3.1.4

AUTOLIST™

The operator can easily change the DEFAULT of all camera sequencing by using the AutoList™
function. AutoList™ sequence lists exist for Monitor A, full-screen and Monitor B through E. An
AutoList™ also exists for the PLAY mode. DEFAULT settings for the lists are all cameras
included, dwell time taken from menu. The DEFAULT dwell time is 3 seconds.
An AutoList™ recording is started in full-screen mode (LIVE or PLAY) by
pressing ALARM and SEQUENCE keys simultaneously. Then select
cameras in order of the sequence desired and at time desired for individual
dwell times. Press the SEQUENCE key to stop recording of the
AutoList™. Dwell times of up (time between key presses) to 30 seconds are allowed. A
maximum of 32 cameras may be put into an AutoList™.
Pressing any key other than a valid camera key or the SEQUENCE key during recording will
void the AutoList™. To return to the DEFAULT of all cameras included in the sequence list,
with a fixed menu programmed dwell time, go to the SEQUENCING menu and change the dwell
time.
NOTE:
The AutoList™ will be erased whenever the FULLSCREEN DWELL setting is
selected in the SEQUENCE menu.
FULLSCREEN DWELL setting with all cameras consecutively sequenced.
3.1.5

PIP DISPLAY: SIZE AND POSITION

The PIP (picture-in-picture) display on monitor-A can be displayed in one of three sizes, and it
can be displayed in one of two positions.
Size selection:
The sizes can be 1/4, 1/9, or 1/16 of full-screen.
Position selection:
The PIP can either be displayed on the lower right hand side of the display, or else on the top
left-hand side of the display.
Changing the PIP size and position:
Select the multi-screen for PIP on Monitor-A. Using the arrow keys changes the PIP
size and position. The up/down arrows will change its position, and the left/right
arrows will change its size, left being smaller and right being larger.
3.1.6

CHANGING POSITIONS AND COLORS OF TITLES

Titles can be displayed as black, gray, or white characters. This feature is selectable for each
camera during either Live or Play modes. Editing titles is done in programming.
20
JVC PROFESSIONAL, IMAGING PRODUCTS
again, or press any camera key, or press the
MULTISCREEN
All Monitor sequences will default to the
key.