SW-D8000U, 16CH. COLOR VIDEO MULTIPLEXER
q
Robot – "ROBOT"
These indicators will appear only if the programmer has selected the corresponding menu option
under VCR SETUP sub menu PLAYBACK FORMAT to decode tapes that were recorded on
alternative multiplexers.
NOTE:
If the programmer attempts to Play back tapes which are not compatible with the
selected format then the tapes will not be decoded correctly.
Adjusting VCR brightness and contrast:
The SW-D8000U provides a simple front panel adjustment to digitally adjust the
contrast and brightness of the Playback signal from the VCR. (This can also be used
to compensate for some VCRs, which output a higher or lower video signal level than
the standard.)
Select PLAY mode and then select the Playback camera image to be enhanced full-screen on
Monitor-A. Use the arrow keys to adjust the signal.
Brightness: Use the up/down arrow keys to adjust the brightness.
Contrast: Use the left/right arrow keys to adjust the contrast.
4.9

ALARM SET UP

The standard SW-D8000U is equipped with one alarm input per camera input, each of which is
normally associated with its corresponding Live video input. An active alarm input can result in an
on-screen indication on both Monitor-A and Monitor-B, a flashing front panel LED, an internal buzzer
and automatic modification of the record list to give the camera in alarm a higher update rate.
This menu item is for alarm inputs. You can specify whether the input for each camera is normally
open or normally closed and if the alarms are latched on (remain active until reset), latched off
(transparent – no buzzer or indicator), or timed out (active until a preset time expires). In addition,
you may program output relay actions, recording parameters and actions.
Indicators:
On-screen display of text "A" in each corresponding cameo of multi-screen displays and 'ALM' on
any full-screen or Monitor-B displays relating to cameras in alarm. The indications will be flashing.
An additional indication in the form of an LED is provided on the front panel, under the
ALARM key. This LED will flash if any Live alarm is active and has not been cleared. An
internal buzzer will sound while any Live alarm is active. This buzzer can be disabled via
the ALARMS sub-menu item BUZZER SETUP.
Clearing Alarms:
To clear all displayed alarms: Press the ALARM key.
MANUAL ALARM ACTIVATION ( PSEUDO ALARM )
Pressing the ALARM and CAMERA number (of the alarm) key simultaneously
can activate a single camera recording. This will cause the alarm number
corresponding to camera number selected to activate.