Whirlpool HybridCare WHD862CHC Use & Care Manual page 15

Heat pump dryer
Hide thumbs Also See for HybridCare WHD862CHC:
Table of Contents

Advertisement

Available languages

Available languages

2. Attach power supply cord to strain relief
Put power supply cord through the strain relief. Be sure that the
wire insulation on the power supply cord is inside the strain relief.
The strain relief should have a tight fit with the dryer cabinet and
be in a horizontal position. Tighten the strain relief against the
power supply cord. Do not overtighten the strain relief screws.
4-Wire Power Supply Connection
IMPORTANT: A 4-wire connection is required for mobile
homes and where local codes do not permit the use
of 3-wire connections.
A. 4-wire receptacle
(NEMA type 14-30R)
B. 4-prong plug
C. Ground prong
D. Neutral prong
3. Prepare ground wire appliance installation
Remove center terminal block screw (B). Remove neutral bond
wire (E) from green external ground conductor screw (A).
E. Spade terminals
with upturned ends
F. 3/4" (19 mm) UL listed
strain relief
G. Ring terminals
4. Connect neutral bond wire and neutral wire
Connect neutral bond wire (E) and neutral wire (white or center)
(C) of power supply cord under center terminal block screw (B).
Tighten screw.
5. Connect ground wire
Connect ground wire (F) (green or bare) of power supply cord
under green external ground conductor screw (A). Tighten screw.
6. Connect remaining wires
Connect remaining wires under outer terminal block screws.
Tighten screws. Insert tab of terminal block cover into slot of
dryer rear panel. Secure cover with hold-down screw. Now, go to
"Venting Requirements."