Displaying heading or speed information

This setting allows to check the heading information of selected sensor, the speed in-
formation of the Log or information about supply voltages.
Fig.30:
Procedure:
Operation of push
after switching
switch 8 (B20) into
the upper position
*
Designations of SEN1 to SEN4 depends on the respective CAN bus address.
The lowest address is SEN1
-- Switch 8 of the DIP--Switch into the upper position.
-- By operating the push button B22 (right side) the display shows the heading value
(the speed or supply voltage) of the selected sensor (see table above).
-- After this check, the switch 8 has to be set into lower position.
3647.DOC010302
Distribution Unit
DIP--Switch B20
B23
DIP--Switch position to adjust output of heading and sped values
button B23
1x
2x
3x
4x
5x
6x
138- -118
OPEN
B22
Display
Heading information
Sen1
Sen2
Sen3
Sen4
PLoG
no information with DV--bus ap-
plication
P--11
11VDC supply voltage
of the I/O PCB
P--35
35VDC operating volt-
age for the 1/6 Step
function of the I/O PCB
50
xxx.x°*
xxx.x°*
xxx.x°*
xxx.x°*
+/--Kts