Selection Of Magnetic Compass - Raytheon Anschütz 138-118 Manual

Table of Contents

Advertisement

4.2.3.8

Selection of magnetic compass

Fig.29:
With this adjustment it is to determine if a magnetic compass is connected to this ap-
plication.
-- Switch 4 of the DIP--Switch (B23) into the upper position.
-- The display shows MAGn.
If this display--information blinks, then it is selected and the distribution unit is
prepared to support a magnetic compass.
-- By operating the push button B22 (right side) the selection is aborted. The display
information does not blink.
-- After adjustment, the switch 4 has to be set into lower position.
Edition: Sept. 05, 2005
Distribution Unit
138- -118
DIP--Switch B20
OPEN
B23
DIP--Switch position to adjust application with Magnetic compass
If a magnetic compass is connected to the Distribution Unit and
the setting is already performed, then the Operation Unit recog-
nized the magnetic compass automatically.
But, if an external sensor as the magnetic sensor is discon-
nected (de--installation), a POWER OFF/POWER ON procedure
has to be performed at the Operation Unit (as a RESET).
B22
49
DISTRIBUTION
UNIT
3647.DOC010302