Adjustment Of Nmea Formats (E10) - Raytheon Anschütz 138-118 Manual

Table of Contents

Advertisement

4.2.3.5

Adjustment of NMEA Formats (E10)

Procedure for NMEA1:
Fig.26:
-- Switch 1 of the DIP--Switch into the upper position.
Number of oper-
ations of push button
after switching switch 1
(B20) into the upper
* to adjust the turn rate, see section 4.2.3.7
Edition: Sept. 05, 2005
Distribution Unit
The Distribution Unit can provide for each output one of three
different data formats (Course bus, NMEA1 and NMEA2).
Selected format can be recognized by the respective
LED colour.
The content of the course bus format cannot be changed, but
both NMEA formats can be adjusted concerning to telegram--
type and repetition rate.
DIP--Schalter B20
B23
DIP--Switch position to adjust the NMEA1 interface
Display
B23
nME1
position
1x
CY. 1
2x
CY.10
3x
cY.10
4x
CY.50
5x
EHdT
6x
CHdT
7x
IHdG
8x
IroT
9x
EroT
138- -118
OPEN
B22
Baudrate
4800Bd
4800Bd
9600Bd
38,4kBd
43
DISTRIBUTION
Interface
NMEA Channel 1
NMEA 1.0sec
NMEA 0.1sec
NMEA 0.1sec
NMEA 0.02sec
HEHDT--Telegram
HCHDT--Telegram
HCHDG--Telegram
TIROT--Telegram*
HEROT--Telegram*
3647.DOC010302