6. At the end of the pyrolytic cycle, all the
numbers will flash and a buzzer will
sound to indicate the end of the
automatic cleaning cycle.
7. Return the function knob to the "0"
position.
8. The door remains locked as long as the
temperature inside the oven returns to
safety levels.
9. Wait for the oven to cool down and
collect the residues deposited inside with
a damp microfibre cloth.
Setting of programmed pyrolytic cycle
It is possible to program the pyrolytic cycle
start time like all other cooking functions.
1. Set the pyrolytic cycle duration.
2. After selecting the pyrolytic cycle
duration (see "Setting for pyrolytic
cycle"), hold the
2 seconds; the display will show the
current time plus the duration previously
set, alternated with the
wording and the
(the latter will flash).
3. Press the
or
5 seconds to set the time at which you
wish to terminate the cleaning cycle.
Cleaning and maintenance
key pressed for
and
symbols
keys within
4. Press the
key to confirm data set;
now, the
symbol will switch off and
the
symbol will be on solid.
When setting the pyrolytic cycle,
pay attention not to turn the function
knob. In this case, data set through
the timer is deleted and must be set
again.
During the first pyrolytic cycle,
unpleasant odours may occur due
to the normal evaporation of oily
manufacturing substances. This is
an absolutely normal phenomenon
which disappears after the first
pyrolytic cycle.
During the pyrolytic cycle the fans
produce a more intense level of
noise due to a greater rotation
speed. This is an absolutely normal
operation, intended to provide
more effective heat dispersal. At
the end of the pyrolytic cycle, the
fans will continue to operate for
long enough to avoid overheating
the walls of adjacent units and the
front of the oven.