The drain hose at the siphon
is blocked
Turn the programme selector to Off.
1.
Pull out the mains plug.
Loosen the hose clamp. Carefully
2.
remove the drain hose; residual
water may leak out.
Clean the drain hose and siphon
3.
connecting piece.
Re-attach the drain hose and secure
4.
the connection point using the hose
clamp.
Filter in the water supply is
blocked
Release water pressure in the supply
hose:
Turn off the water tap.
1.
Select the Βαμβακερά (Cottons)
2.
(activate SpeedPerfect setting)
programme.
If your appliance with
Note:
intelligent dosing system
need to deactivate the intelligent
dosing system.
Select the Έναρξη/Προσθήκη
3.
ρούχων (Start/Reload) button. Allow
the programme to run for approx. 40
seconds.
Turn the programme selector to Off.
4.
Pull out the mains plug.
5.
*
Depending on the model
Clean the filters:
1.
2.
3.
*
, you also
4.
Cleaning and maintenance
Disconnect the hose from the rear of
the appliance.
Use pliers to remove the filter.
Clean the filter with a small brush.
Connect the hose and check for
leaks.
en
45