Start up
3. HiCoat-ED Pump
Overall air quantity
This setting is recommended for standard coating quality.
Feed air
3
(Nm
/h)
1.0
2.0
3.0
3.5
2.3
Performing a color change
Hint
When changing colors, all powder transporting components must be cleaned
thoroughly.
2.3.1 HiCoat-ED Pump - F
The control unit (with AFC technology) for the HiCoat-ED Pump - F is switched to automatic
purging. The HiCoat-ED Pump is completely cleared of residual powder during this procedure.
Please consult Wagner Service if the control unit is not yet equipped with this purging
procedure function, or proceed as in the following description for the HiCoat-ED Pump - P.
08/2008
Powder hose inside diameter 10 mm
3.5 Nm
Powder hose length
6 m
Powder output quantity
(g/min)
55
175
280
320
0241886
– HiCoat-ED Pump
3
/h
Powder hose length
12 m
Powder output quantity
(g/min)
20
135
215
250