Maintenance and rectification of malfunctions
3.3

Disposal

Wagner or one of our dealers will take back your used Wagner waste electrical or electronic
equipment and will dispose of it for you in an environmentally friendly way. Please ask your
local Wagner service center or dealer for details or contact us direct.
4.

Rectification of malfunctions

Malfunction
Insufficient powder
delivery
Pulsed powder delivery
08/2008
Only for EU countries
Do not dispose of electric tools together with household waste
material!
In observance of the European Directive 2002/96/EC on waste electrical
and electronic equipment and implementation in accordance with
national law, this product is not to be disposed of together with household
waste material but must be recycled in an environmentally friendly way!
Cause
- Collector-nozzle clogged
- Collector-nozzle worn
- Leak between container and
HiCoat-ED Pump
- Insufficient overall air
- Collector-nozzle not mounted
correctly
0241886
– HiCoat-ED Pump
04_Entsorgung.doc
Remedy
- Replace and clean collector-
nozzle
- Replace collector-nozzle
- Replace O-ring
- Increase overall air quantity
- Clean thread of the outer nut
and tighten nut securely