Si001362E
Step
4
Remove the 2 screws.
Separate the humidifier
5
fan assembly from the
damper assembly.
6
Disconnect the damper
motor lead wire.
7
Turn the damper
assembly back and
disconnect the
terminals of the limit
switch.
Removal Procedure
Procedure
Damper motor lead wire
Humidifier Fan Assembly / Damper Assembly
(R19586)
The humidifying fan
assembly should be
replaced as an assembly
set. (Disassembling of the
assembly can cause a
noise.)
Humidifier
fan assembly
Damper
assembly
(R19587)
(R19588)
Limit
switch
(R19589)
Points
9