7.5
Capacity Control – Zero Adjustment
Individual capacity control is provided for each pump head by means of a
micrometer located directly behind the respective pump head.
Should it become necessary to reset the mechanism, the procedure is as follows:
7.5.1
With pump running, screw micrometer mechanism in until piston
movement is just stopped. This can be sensed when resistance to turning
becomes constant.
remove micrometer mechanism
NOTE
On some units, oil level will be above micrometer and spillage
will occur on removal. Hence measures should be taken to catch
spillage or tilt pump forward to avoid spillage.
7.5.2
Clamp micrometer anvil in vice and holding the barrel to prevent rotation,
loosen the socket set screw located in rear of barrel. This set screw locks
the barrel to the anvil.
7.5.3
Now, holding the mounting flange to prevent it turning, rotate the barrel
until it reads zero.
7.5.4
Again hold barrel to prevent it rotating and retighten set screw.
7.5.5
Set micrometer at 100% and refit to pump.
CAUTION
All major mechanical repairs should be undertaken by Acromet's specialist
servicing workshop in Melbourne.
despatched in one day
MP3000PR 001 to 010 Plunger PumpUpdated January 2017
Stop pump.
Should oil spillage have occurred, add oil to correct level
before starting pump.
Unfasten both mounting screws and
In most cases a pump can be repaired and
Page 8
Series 3000PR