Summary of Contents for Acromet ACRO-SMART AS.1

  • Page 1 MART IAPHRAGM NCOMPLICATED CONOMICAL CCURATE LECTRONIC ETERING TANDARD IN HEMICAL ETERING...
  • Page 2 Acro-Smart Electronic Series January 2017 LABORATORY ACCURACY INDUSTRIAL DURABILITY Acromet offers competitively priced chemical metering to suit all applications  Motor driven electronic series with continuous proportional metering  0.37 kW 415/3/50 motor with option for 240/1/50  IP.66 Motor and Electronic enclosure ...
  • Page 3 Acro-Smart Electronic Series January 2017 Acro-Smart Electronic Series...
  • Page 4: Table Of Contents

    Acro-Smart Electronic Series January 2017 Contents SAFETY ....................2 General ....................2 Mechanical Precautions ................2 Electrical Precautions ................2 INTRODUCTION ..................3 INSTALLATION ..................3 PIPING ...................... 3 General ....................3 Suction ....................4 Discharge ..................... 5 Piping Arrangement ................6 OPERATION .....................
  • Page 5 Acro-Smart Electronic Series January 2017 Important – For Manual Capacity Pumps Please refer to Clause 6 “Capacity Adjustment” on page 8, 9 & 10 and familiarise yourself with the contents prior to starting the pump. The Manual Capacity Adjustment Default setting for this pump has been set to;...
  • Page 6: Safety

    Acro-Smart Electronic Series January 2017 METERING PUMPS ACRO-SMART SERIES SAFETY General Please read and familiarise yourself with all sections of this and other equipment manuals before proceeding with installation.  Observe all standard precautions which apply to moving machinery.  Observe all standard precautions which apply to electrical equipment, drives and controls.
  • Page 7: Introduction

    Acro-Smart Electronic Series January 2017 INTRODUCTION Acromet metering pumps are designed and manufactured for long, low maintenance service life and when properly applied, will give many years of consistent accurate metering and trouble free operation. The following instructions should be read and followed to correctly install and operate the pump and ensure optimum pump life and performance.
  • Page 8: Suction

    Acro-Smart Electronic Series January 2017 4.1.4 Piping should be as short and straight as possible and arranged to avoid loops or pockets where gas may accumulate. 4.1.5 All piping should be separately supported close to the pump to avoid imposing pipe loads on the pump. When handling high or low temperature liquids, measures should be taken to prevent distortion of piping imposing loads on the pump.
  • Page 9: Discharge

    Acro-Smart Electronic Series January 2017 Discharge 4.3.1 Should it be necessary to install an isolating valve in the discharge line, a relief valve must be installed between the pump and isolating valve. 4.3.2 The 2500 Metering Pump, being a positive displacement pump, will be damaged if operated against a closed valve.
  • Page 10: Piping Arrangement

    Acro-Smart Electronic Series January 2017 Piping Arrangement WRONG CORRECT Should it be necessary to install an isolating valve in the discharge line, a relief valve must be installed in the line between the pump and isolating valve. Metering pumps are positive displacement pumps and produce pulsating flow. Consequently there is considerable line pressure loss and suction piping should be sized to ensure adequate NPSHA.
  • Page 11: Operation

    Acro-Smart Electronic Series January 2017 OPERATION Before Starting 5.1.1 Ensure the pump will be operated within its specification. 5.1.2 Check gearbox oil level. Prior to leaving factory, each pump is filled to the correct level with the recommended grade of oil (see maintenance section).
  • Page 12: Capacity Adjustment

    Acro-Smart Electronic Series January 2017 CAPACITY ADJUSTMENT 4-20 mA Automatic Adjustment This pump is capable of accepting a 4-20 mA input signal to operate the capacity adjustment automatically. Ensure when connecting your 4-20 mA two (2) wire input signal are connected to Plug “D”...
  • Page 13 Acro-Smart Electronic Series January 2017 Manual Adjustment Standard manual capacity adjustment is by means of a key pad on the digital set point box mounted on the side of the electric motor. The manual capacity parameters for your pump have been pre-set and do not need any adjustment.
  • Page 14 Acro-Smart Electronic Series January 2017 CAUTION When power is turned off, or a power failure has occurred, the Blue LED lights on the key pad, will flash ON and OFF, when the power is restored. To restart the pump press the green start button to restore the preset default (L/Hr) setting and then adjust the manual capacity button to your...
  • Page 15: Maintenance

    ETERING RETURNED FOR MAINTENANCE THAT HAS NOT BEEN SUITABLY CLEANED It is an Acromet Quality Assurance policy that all equipment returned for repair or service be supplied with a completed copy of the 'Equipment Decontamination Advice' form, as shown on page 37 of this manual.
  • Page 16: Diaphragm

    After the new diaphragm has been fitted, calibration should be checked and monitored until diaphragm has stabilised. All major mechanical repairs should be undertaken by Acromet's specialist servicing workshop in Melbourne. In most cases a pump can be repaired and despatched in one day.
  • Page 17: Troubleshooting

    Acro-Smart Electronic Series January 2017 TROUBLESHOOTING Trouble Cause Corrections Pump does not start. Blown electrical. Fuse. Check cause and change to suitable capacity fuse Electrical overload relay Change relay capacity to trips. correct value. Electrical wiring breakdown Change or reconnect. or defective contact.
  • Page 18 Acro-Smart Electronic Series January 2017 Trouble Cause Corrections Reduced pump flow Valve clogged. Clean. rate or unstable rate. Worn valve seat. Replace seat or valve. Flow meter incorrect. Inspect meter, repair or change. Leakage from relief valve. Inspect, repair or change. Air leaking into suction Check for leak source and piping...
  • Page 19 Acro-Smart Electronic Series January 2017 Trouble Cause Correction Excessive pump flow Pressure difference across Increase pressure rate. pump less than 20 KPa difference (ie install back Flow continues after pressure valve). pump has stopped. Discharge line too long or Reduce length and/or diameter too small increase diameter.
  • Page 20: Acro-Smart Electronic Series Metering Pump

    Acro-Smart Electronic Series January 2017 ACRO-SMART ELECTRONIC SERIES METERING PUMP Drive End (Simplex) – Side Elevation Acro-Smart Electronic Series...
  • Page 21: Drive End (Simplex) - Side Elevation - Parts List

    Acro-Smart Electronic Series January 2017 Drive End (Simplex) – Side Elevation - Parts List ITEM PART NO DESCRIPTION NOTES E-42 WORM ◊ 10-01-11 (DRIVE MOTOR) 08-12-02 OIL FILL PLUG 10354 WORM EXTENSION SHAFT □ 10302 PRIMARY PISTON 11-01-21 CIRCLIP (STRIKER SHAFT) 09/03/06 WAVE WASHER 10311...
  • Page 22: Drive End (Simplex) - End Elevation

    Acro-Smart Electronic Series January 2017 Drive End (Simplex) – End Elevation Acro-Smart Electronic Series...
  • Page 23: Drive End (Simplex) - End Elevation - Parts List

    Acro-Smart Electronic Series January 2017 Drive End (Simplex) – End Elevation - Parts List ITEM PART NO DESCRIPTION NOTES 08-01-74 SCREW (MOTOR) 09-02-24 SPRING WASHER (MOTOR)  10355 WORM WHEEL ◊ 06-04-07 BUSH (MAIN SHAFT) 10325-1 MAIN SHAFT  08-12-02 DRAIN PLUG AS SPEC DRIVE MOTOR...
  • Page 24: Liquid Head Section Drawings

    Acro-Smart Electronic Series January 2017 Liquid Head Section Drawings Acro-Smart Electronic Series...
  • Page 25 Acro-Smart Electronic Series January 2017 Acro-Smart Electronic Series...
  • Page 26 Acro-Smart Electronic Series January 2017 Acro-Smart Electronic Series...
  • Page 27 Acro-Smart Electronic Series January 2017 Acro-Smart Electronic Series...
  • Page 28 Acro-Smart Electronic Series January 2017 Acro-Smart Electronic Series...
  • Page 29 Acro-Smart Electronic Series January 2017 Acro-Smart Electronic Series...
  • Page 30 Acro-Smart Electronic Series January 2017 Acro-Smart Electronic Series...
  • Page 31 Acro-Smart Electronic Series January 2017 Acro-Smart Electronic Series...
  • Page 32 Acro-Smart Electronic Series January 2017 Acro-Smart Electronic Series...
  • Page 33 Acro-Smart Electronic Series January 2017 Acro-Smart Electronic Series...
  • Page 34 Acro-Smart Electronic Series January 2017 Acro-Smart Electronic Series...
  • Page 35 Acro-Smart Electronic Series January 2017 Acro-Smart Electronic Series...
  • Page 36: Calibration Of A Metering Pump

    Acro-Smart Electronic Series January 2017 CALIBRATION OF A METERING PUMP To perform a calibration test on the delivery rate you will require a stop watch and materials necessary to perform a series of simple calculations. To utilise this system efficiently, the following procedure should be followed whilst the pump is operating.
  • Page 37: Calibration Cylinder - Installation Guide

    Acro-Smart Electronic Series January 2017 CALIBRATION CYLINDER – INSTALLATION GUIDE LOCATION: Install the calibration cylinder as shown in Figure 1. The cylinders must be installed in the suction piping in a vertical position and as close as possible to the suction tank. Remember the location should make allowance for sufficient free space around the calibration cylinder for easy reading of graduations.
  • Page 38: Series 500 Valve Instructions

    Valve operating pressure is controlled by the spring (8) and can be increased or decreased by varying the spring preload. At date of purchase, Acromet will adjust the valve to meet customer's requirements. To alter or set operating pressure at site, it is necessary for a pressure gauge with...
  • Page 39 Acro-Smart Electronic Series January 2017 TYPICAL INSTALLATION LAYOUT 1. Supply Tank 2. Metering Pump 3. Pressure Relief Valve 4. Pulsation Dampener 5. Back Pressure Valve 6. Pressure Gauge 7. De-pressurising Valve Acro-Smart Electronic Series...
  • Page 40 Acro-Smart Electronic Series January 2017 GENERAL ASSEMBLY 502 SERIES BACK PRESSURE VALVE Acro-Smart Electronic Series...
  • Page 41 Acro-Smart Electronic Series January 2017 GENERAL ASSEMBLY 502 SERIES PRESSURE RELIEF VALVE Acro-Smart Electronic Series...
  • Page 42: Acro-Smart Wiring Connection Details

    Acro-Smart Electronic Series January 2017 ACRO-SMART WIRING CONNECTION DETAILS (Where Fitted) Pin Connection Diagram. A. Motor Parameters. (Possible options)  Motor “On” Status.  Motor over temperature status. B. Control Inputs. (Possible options)  Supply Tank Low Level.  Flow Meter Input. ...
  • Page 43: Appendix

    Acro-Smart Electronic Series January 2017 APPENDIX EQUIPMENT DECONTAMINATION ADVICE DOC. No. SD-19.0-1 Acro-Smart Electronic Series...
  • Page 44: Equipment Decontamination Advice Doc. No. Sd-19.0-1

    Acro-Smart Electronic Series January 2017 Acro-Smart Electronic Series...
  • Page 45 Acro-Smart Electronic Series January 2017 Acro-Smart Electronic Series...