Piping Arrangement - Acromet 3000 Series Manual

Diaphragm metering pump
Table of Contents

Advertisement

4.4

Piping Arrangement

suction to avoid damage by running the unit dry
WRONG
Should it be necessary to
install an isolating valve in
the discharge line, a relief
valve must be installed in
the line between the pump
and isolating valve.
Metering pumps are positive displacement pumps and produce pulsating flow. Consequently there
is considerable line pressure loss and suction piping should be sized to ensure adequate NPSHA. If
piping extends for a considerable distance a suitable break tank or pulsation dampener should be installed near
pump.
the pump.
Avoid pockets or loops in piping where gas may accumulate.
Where the pump discharge line connects
with a high pressure line, install a
non return valve as a safety precaution
The presence of solids in the pumped liquid can cause incorrect
pump valve operation and affect metering accuracy.
If solids are present install a strainer with 150 to 200 mesh
and large mesh surface in order to keep pressure drop as small
as possible and ensure that strainer does not become
quickly clogged.
NOTE
The diagrams above are representational and are intended as a guide
only. For specific system design or advice please consult a pump systems
engineer or contact Acromet.
MP3000PR 001 to 010 Plunger PumpUpdated January 2017
Please note Plunger Pumps must have a flooded
WRONG
.
CORRECT
CORRECT
CORRECT
Series 3000PR