Items
Adjustment
N)
Sensitivity
Receiver
Confirmation
O)
Timing
Confirmation
(P)
RSSI Level
*
Confirmation
Point
-
Follow steps 1 to 3 of (J) above.
4.Set DECT tester power to -88dBm.
5.Confirm that the BER is < 1000ppm.
-
Follow steps 1 to 3 of (J) above.
4.Confirm that the Timing accuracy is < ± 0.5ppm.
-
Follow steps 1 to 3 of (J) above.
4.Set DECT tester power to -81dBm.
5.Execute the command "readrssi".
6.Confirm that the returned value is 0x09 (hex) ~
0x19 (hex).
7.Set DECT tester power to -63dBm.
8.Execute the command "readrssi".
9.Confirm that the returned value is 0x16 (hex) ~
0x26 (hex).
Procedure
103
Check or
Replace
Parts
IC1, IC3,
L2,
C54, C60,
C61,
C62, C63,
C64,
C65, C66,
C67,
C69, C81,
C82,
C56, R58,
R55, R76
IC1, IC3,
L2,
C54, C60,
C61,
C62, C63,
C64,
C65, C66,
C67,
C69, C81,
C82,
C56, R58,
R55, R76
IC1, IC3,
L2,
C54, C60,
C61,
C62, C63,
C64,
C65, C66,
C67,
C69, C81,
C82,
C56, R58,
R55, R76