Configuring "Gateway Modem - Ebyte E90-DTU-V8 User Manual

Hide thumbs Also See for E90-DTU-V8:
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co.,Ltd.
E90-DTU(433L30E)-V8 User Manual

2.4.2. Configuring "Gateway Modem"

Step 1: Turn on the power and connect the PC and the "Gateway Radio" with a network cable;
Step 1: Perform factory configuration on the "Gateway Radio", press and hold the Reload button until the indicator
lights are all on;
Step 2: Modify the IPv4 configuration of the PC, use a static IP, and ensure that the "gateway radio" and the PC are
in the same network segment. The factory default IP is 192.168.4.101, so configure the static IP of the PC as
192.168.4.100 as shown in the following figure: