Problem solving

Condition
A lot of oil entered the
condensate treatment
device.
The service indicator
(5 - View of the unit)
rises
Cloudy condensate at
the outlet.
22
Fault
Compressor
malfunctioning
Too much
condensate flows into
the condensate
treatment device.
Improper sizing.
Remedy
Replace all filters. Clean the vessels. Check the
compressor.
Check the compressor FAD (see section
It is possible that the compressor produces stable and
strong emulsions due to various environmental and working
conditions. Check if the sizing was done properly. FAD of
the installation should be equal to or lower than the
recommended value and correct filter media must be
selected based on the oil type. See section
Instruction book
Technical
data).
Technical
data.