4

Operating instructions

4.1

Putting into operation

QOCS 106 – QOCS 1325
1. Remove the lid of the housing. Take out the oleophilic filter.
2. Remove the cartridge by removing 3 screws (6mm cross head).
Remove the protecting plug from the cartridge hose and the black plastic plug over the outlet
location as shown in below figure (1, 2).
Place the cartridge back and secure it with screws. Make sure that the o-ring is inserted
properly.
3. Check that the muffler is place properly and exactly below the condensate inlets.
4. Pour clean water into the unit until the water comes out of the condensate outlet.
5. Put the oleophilic filter on the water surface in the housing. Do not push the filter down.
6. Put the lid back on and check that the service indicator is free to move.
QOCS 2650
1. Remove the lid of the housing. Take out the oleophilic filter.
2. Remove the cartridge by removing 4 screws (6mm cross head).
Remove the protecting plug from the cartridge hose (only on the first cartridge) and the black
plastic plug over the outlet location as shown in below figure (1, 2).
Place the cartridge back and secure it with screws. Make sure that the o-ring is inserted
properly.
16
The plastic bag of the filters must be removed. Do not remove the net around the filters.
Unit must not be placed under direct sunlight.