3.4 Ethernet (LAN) Interface Board

This section provides an overview of the Ethernet (LAN) interface board. For details
about this board, refer to the separate manual.
Panel button operati on
Board operations are performed using the panel button on the Ethernet board. You
can use the button to print setup information and to return the board to its factory
settings.
 Printing network setup information
Press the panel button.
 Entering setting mode
Hold down the panel button. A buzzer* will sound once to indicate that setting mode
has been entered.
• You can use setting mode to read factory settings and to print firmware information.
• If you do not perform any operation for three seconds while in setting mode, a buzzer* will
sound once to indicate the board has returned to normal mode.
* Depending on settings, the buzzer may not sound.
 Returning to factory settings
Enter the board setting mode, and then hold down the panel button. This returns
the board to its factory settings.
CAUTION
 The board will automatically restart after this operation is complete.
 If settings are configured to obtain an IP address from a DHCP server automatically, the
new IP address may be different from the previous one.