Toshiba MMD-UP0721HP-E1 Installation Manual page 29

Table of Contents

Advertisement

Check code
Wired remote
controller display
L02
L02
Detected indoor unit address
L03
L04
L04
L05
L06
L06
No. of indoor units with priority
L07
L08
L08
L09
L10
L10
L11
L11
Detected indoor unit address
L12
L12
01: Flow Selector unit installation trouble
L13
L13
Detected indoor unit address
L14
L14
Detected indoor unit address
L17
L17
L18
L18
Detected indoor unit address
L20
L22
01: Duplication of Flow Selector unit address
L24
L24
02: Indoor unit operation mode priority setting
L28
L28
L29
L29
*1 Inverter quantity information
L30
L30
Detected indoor unit address
L31
P01
P03
P03
1
: Comp. 1 side
P04
P04
2
: Comp. 2 side
1
: Comp. 1 side
P05
P05
2
: Comp. 2 side
1
: Comp. 1 side
2
: Comp. 2 side
P07
P07
04: Heat sink
P10
P10
Detected indoor unit address
P11
P11
P12
P13
P13
01: TS condition
P15
P15
02: TD condition
01: PMV5
P16
P16
02: PMV6
03: SV7
P17
P17
P18
P18
0#: 4-way valves
1#: 4-way valve1
P19
P19
2#: 4-way valve2
*Put in outdoor unit No. in [#] mark.
P20
P20
55-EN
Outdoor unit 7-segment display
Auxiliary code
Wireless remote controller
Sensor block display of receiving unit
Operation
Timer
Ready
Flash
SIM
[
SIM
[
SIM
\
SIM
[
SIM
[
SIM
[
SIM
[
SIM
[
SIM
\
SIM
\
SIM
\
SIM
\
SIM
\
SIM
\
SIM
\
SIM
\
SIM
\
SIM
\
SIM
\
SIM
\
SIM
\
ALT
[
ALT
[
ALT
[
ALT
[
ALT
[
ALT
[
ALT
[
ALT
[
ALT
[
ALT
[
ALT
[
ALT
[
ALT
[
ALT
[
ALT
[
– 28 –
Check code name
Model mismatch of indoor and outdoor unit
Indoor unit incompatible with A2L (R32) refrigerant
Indoor unit centre unit duplicated
Outdoor unit line address duplicated
Duplicated indoor units with priority (Displayed in indoor unit with priority)
Duplicated indoor units with priority
(Displayed in unit other than indoor unit with priority)
Group line in individual indoor unit
Indoor unit group/Address unset
Indoor unit capacity unset
Outdoor unit capacity unset
Flow Selector unit not connected
Flow Selector unit system trouble
Safety device setting unmatch
Safety device nonconformity
Outdoor unit type mismatch trouble
Flow Selector unit trouble
Duplicated central control addresses
There is a DX-kit (heat source capacity command) non-compliant machine in
the group (DDC control, TA control and TF control are mixed)
Flow Selector unit setting trouble
Too many outdoor units connected
No. of inverter trouble
Indoor unit outside interlock
Extended I/C trouble
Indoor fan motor trouble
Discharge temp. TD1 trouble
High-pressure SW system operation
Phase missing detection/Power failure detection
Inverter DC voltage trouble (comp.)
Heat sink overheat trouble
Heat sink dew condensation trouble
Indoor unit overflow trouble
Outdoor heat exchanger freezing trouble
Indoor unit fan motor trouble
Outdoor liquid back detection trouble
Gas leak detection
Injection circuit trouble
Discharge temp. TD2 trouble
Discharge temp. TD3 trouble
4-way valve inverse trouble
High-pressure protective operation
Judging device
I/F
Indoor unit
I/F
I/F
I/F
Indoor unit
Indoor unit, I/F
Indoor unit
I/F
I/F
I/F
I/F
I/F
I/F
I/F
Indoor unit
Indoor unit
I/F
I/F
I/F
Indoor unit
I/F
Indoor unit
I/F
Inverter
I/F
Inverter, I/F
Indoor unit
I/F
Indoor unit
I/F
I/F
EN
I/F
I/F
ID
I/F
I/F
ID
I/F
56-EN