Programming mode
To enter programming mode turn the ignition on then hold down both buttons on the remote control for 3
seconds; the alarm will now start to chirp (one chirp, then 2 chirps, then 3 chirps and finally 4 chirps). Select
the item to be programmed by releasing the buttons after the appropriate chirp count.
Programmable items:
1 chirp:
Movement sensitivity
3 chirps:
Auto re-arm
2 chirps:
Arm/disarm tones
4 chirps:
Auto arming
Once an item has been selected the LED will flash and alarm will chirp to show the current setting.
To change the setting, press the large remote button to change up or the small button to change down, the
setting will roll round in either direction.
To exit and save the desired setting, turn the ignition off or wait 30 seconds without pressing either button.
The alarm will give one long beep when exiting programming mode.
Movement sensitivity LED flashes
The LED will flash in sets of 1 up to 4 indicating the current setting:
1.
Off
2.
Low sensitivity
3.
Medium sensitivity (default)
Arm/disarm tones LED flashes
The LED will flash to indicate the chosen option, press large button to progress to next level.
1
flash: Tones Off (default)
2
flashes: Tones On Quiet
Automatic Arming LED flashes
The LED will flash to indicate the chosen option, press large button to progress to next level.
1
flash: Off (default)
2
flashes: Arm after 30 secs
Auto re-arm LED flashes
The LED will flash in sets of two if the auto re-arm function is on and single flashes if the auto re-arm function
is off. Default is off. When enabled, if the alarm is disarmed and left for 30 sec without manual arming or
turning the ignition on then the alarm/immobiliser will automatically re-arm.
Reset to defaults LED flashes
To reset the alarm to the factory default setting set the LED to flash twice. To exit without resetting to defaults
set the LED to flash once.
Adding/ removing remote controls
With the alarm is in disarmed state turn the ignition on/off/on/off/on within 7 seconds. The LED will start to
flash rapidly for 3 seconds then flash slowly a maximum of 9 times. Count the LED flashes, and then switch the
ignition off when the LED flash equals that of the first digit of the PIN code. Zero would be input by
immediately switching the ignition off after the rapid flashing of the LED.
Switch the ignition on and start the LED count process again for the 2
and fourth digits. If the PIN code has been entered correctly the alarm will chirp twice. If the PIN code is
entered incorrectly the alarm will chirp three times, at this point the PIN code can be entered twice more
before ignoring the PIN code entry for two minutes.
Pressing a remote control, existing or new will add this to the system and delete all previously entered remote
controls. Press each remote control that you require to be added; the siren will chirp and the LED will flash for
acknowledgement of the remote control. If the maximum number of remotes has been reached then a long
beep will be heard indicating that the last remote pressed has not been saved.
Turning on the ignition, pressing an already entered remote control or not pressing a button on a new remote
control for 30 seconds will exit this mode. On exit the alarm will chirp twice and the LED will flash the number
of stored remotes. A maximum of 6 remotes can be stored.
5
chirps: Reset to defaults
4.
High sensitivity
3
flashes: Tones On Loud
3
flashes: Arm after 1 min
4
flashes: Arm after 2 mins
nd
digit of the PIN. Repeat for the third
Alarm with Single Circuit Immobilisation
User Guide
Revision 7 | December 2017
Thank you for choosing the DATATOOL
quad alarm with single circuit immobilisation capability.
This security system is designed as a deterrent and is not in itself a guarantee
against theft prevention. We advise you that the more difficult you make your
machine to be stolen, the lower the potential theft risk.
Applying common sense and securing your machine with additional security
every time you park plays a large part in this.
Please retain this user guide for future reference.
The Remote Control
All DATATOOL
EVOPLUS
systems come with 2 remote controls as
standard. It is possible to add up to 4 extra remote controls (6 in total).
The large button controls the main arm/disarm functions of the system.
The smaller button is used to initiate secondary functions such as
movement sensor deletion (transport mode) and locate. Detailed
operating instructions follow further in this manual.
When either button is pressed on the remote control, the LED will flash
briefly to confirm the button has been pressed. If the button is held
depressed the LED will flash approximately once a second for a maximum
25 flashes.
Changing the Remote Battery
Each remote control contains a single long life lithium battery (CR2016). To replace the battery, locate the
recess in the casing edge and gently prise the upper and lower casing of the remote apart at this point.
The battery is retained by a spring and can be replaced by simply sliding the battery out from under the
spring, noting the polarity and replacing with new. Ensure the battery polarity is correct when installing
the new battery. Align the two casing halves and squeeze firmly to click the casing back together, ensuring
the joint is even around the circumference.
www.datatool.co.uk
Datatool is a brand of Scorpion Automotive Ltd
Scorpion House, Drumhead Road, Chorley North Business Park
Chorley, Lancashire, UK.
EVOPLUS
EVOPLUS
- a motorcycle, scooter and
of

Advertisement

loading

Summary of Contents for Datatool EVOPLUS

  • Page 1 Datatool is a brand of Scorpion Automotive Ltd Turning on the ignition, pressing an already entered remote control or not pressing a button on a new remote Scorpion House, Drumhead Road, Chorley North Business Park control for 30 seconds will exit this mode.
  • Page 2 PIN code can be entered twice more before PIN code entry is disabled for two remote control button must be pressed within 10 seconds otherwise the alarm will sound. minutes. www.datatool.co.uk DATATOOL EVOPLUS User Guide...