4-3. Louver Setting - Toshiba RAV-SM182UTP-UL Owner's Manual

Hide thumbs Also See for RAV-SM182UTP-UL:
Table of Contents

Advertisement

Available languages

Available languages

4-3. Louver setting

Swing type
* Select the louver swing type from the standard swing, dual swing or cyclic swing.
Carry out the setting operation while the indoor unit is stopped. (Turn off the air conditioning unit before starting the
setting operation.)
Before setting
Louver setting
1.Swing type
2.Louver lock
Return
Set
Swing type
Standard
Dual
Cycle
Return
Fix
NOTE
• "No function" appears on the display for the models not equipped with the Swing type setting.
• Push the [
CANCEL] button to stop the setting procedure. No setting has been made and the screen returns to
"Louver setting".
25-EN
OM_1115350256-1_EN_FR_ES.indb 13
OM_1115350256-1_EN_FR_ES.indb 13
1
Push the [
] / [
] button to select
"3. Louver setting" on the menu screen, then
push the "
Set" [
F2] button.
Set
2
Push the [
] / [
] button to select
"1. Swing type", then push the "
Set"
Set
[
F2] button.
3
Push the [
] / [
] button on the
"Swing type" screen to select the swing type.
Refer to the Owner's Manual supplied with the
indoor unit about the swing type.
4
Push the [
MENU] button.
" Setting" appears on the display.
The unit selection screen appears when the group
control is used. Push the [
CANCEL] button
on the unit selection screen to finish the setting
operation. " Setting" appears on the display.
– 13 –
▼ Standard swing
All four louvers swing simultaneously at the same
angle.
Swing
▼ Dual swing
Adjoining louver alternately swing horizontally and
downward.
Horizontal
Horizontal
Downward
Downward
Horizontal
Horizontal
Downward
Downward
▼ Cyclic swing (Recommended for cooling)
All four louvers swing at different times like waves.
5/4/2565 BE 09:52
5/4/2565 BE 09:52
26-EN

Advertisement

Table of Contents
loading

Table of Contents