1. HD signal emitter (or Leader: 1080i / No.9 signal)
2. Wattmeter
-
Make sure the set is aged for 30 minutes or more before adjustment.
(Do not switch off during or after aging.)
-
Voltage 230V 50Hz (variation within 1%)
-
Volume at minimum and screen size at "16:9"
Setting
Component input, dynamic, standard
1. Connect the set's AC power to the wattmeter.
2. Input the signal (top half: color bar, Bottom half: Horizontal 10steps bar).
3. Select the "APL MULT" item in the Serivice1.
4. Adjust APL MULT so the set's power consumption is
TH-42PE55E
TH-37PE55E
1. The initial data are
0×1E for 37/42SD (A0-0626)
2. The power and data are in reverse relationship
(Lower the data to raise the power.)
-Raising direction (
-Lowering direction (
12. Hotel mode
1. Purpose
Restrict a function for hotels.
2. Access command
- Enter to the Service 2 Mode.
- Press Information button on remote control and entry to the
- Set the data of EEPROM(ADDRESS 140) to 80.
- Press the OK button to memorize the data.
PDF created with pdfFactory Pro trial version
Instrument Name
Procedure
317 (+5 / -10) W
247 (+5 / -10) W
):20
1F
):20
1A
(
):20
1F
(
):20
1A
EAROM EDITOR Mode.
Connection
COMPONENT input terminal
Connect the AC power of
the adjustment set to the
wattmeter.
40
www.pdffactory.com
Remarks
Remarks
According to the line
condition,100V can be used