Technical Specifications - HP Compaq dc5800 Specifications

Business pc
Hide thumbs Also See for Compaq dc5800:
Table of Contents

Advertisement

QuickSpecs

Technical Specifications

Unit Environment and Operating
Unit Environment and Operating
Unit Environment and Operating
Unit Environment and Operating
Conditions
Conditions
Conditions
Conditions
General Unit Operating Guidelines
Keep the computer away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure that unit is
operated within the specified operating range.
Leave a 10.2 cm (4 in) clearance on all vented sides of the computer to permit the required airflow.
Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near each other that they are subject to each other's re-
circulated or preheated air.
Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint, dust and other foreign
matter can block the vents and limit the airflow.
If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must be provided on the
enclosure, and the same operating guidelines listed above will still apply.
Temperature Range
Temperature Range
Temperature Range
Temperature Range
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
Maximum Altitude (unpressurized)
Maximum Altitude
Maximum Altitude
Maximum Altitude
* Operating temperature is de-rated 1.0 deg C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level, no direct sustained
sunlight. Maximum rate of change is 10 deg C/Hr. The upper limit may be limited by the type and number of options installed.
Power Supply
Power Supply
Power Supply
Power Supply
Operating Voltage Range
Rated Voltage Range
Rated Line Frequency
Operating Line Frequency Range
Rated Input Current
Heat Dissipation
Power Supply Fan
ENERGY STAR Compliant
FEMP Standby Power Compliant
(<2W in S5 – Power
Off)**
Power Consumption in ES Mode –
Suspend to RAM (S3)
(Instantly Available PC)
Microtower
Microtower
Microtower
Microtower
Operating: 10% to 90% (non-condensing at ambient)
Non-operating: 5% to 95% (non-condensing at ambient)
Microtower
Microtower
Microtower
Microtower
300-watt BTX power
supply – Passive PFC
efficient*
115v/230v line switch
supply – Active PFC
90 to 132VAC, or 180
to 264VAC
100 to 127VAC, or
200 to 240VAC
50/60 Hz
47–63 Hz
8A/4A
Typical 315 btu/hr
Typical 270 btu/hr
(79 kg-cal/hr)
Maximum 1575 btu/hr
Maximum 1280 btu/hr
(397 kg-cal/hr)
Variable speed fan
Variable speed fan
X
<4W
DA - 12863
Canada — Version 24 — July 31, 2009
HP Compaq dc5800 Business PC
HP Compaq dc5800 Business PC
HP Compaq dc5800 Business PC
HP Compaq dc5800 Business PC
Operating: 50° to 95° F (10° to 35°
Non-operating: -22° to 140° F(-30° to 60° C)
Operating: 10,000 ft (3048 m)
Non-operating: 30,000 ft (9144 m)
300-watt 85%
240-watt BTX power
BTX power
supply – Active PFC
115v/230v line switch
90 to 264VAC
90 to 132VAC, or 180
to 264VAC
100 to 240VAC
100 to 127VAC, or
200 to 240VAC
50/60 Hz
47–63 Hz
5A/2.5A
Typical 315 btu/hr
(68 kg-cal/hr)
(79 kg-cal/hr)
(322 kg-cal/hr)
1260 btu/hr
(317 kg-cal/hr)
Variable speed fan
X
X
<3W
Small Form Factor
Small Form Factor
Small Form Factor
Small Form Factor
C)*
Small Form Factor
Small Form Factor
Small Form Factor
Small Form Factor
240-watt 85%
efficient* BTX power
supply – Active PFC
90 to 264VAC
100 to 240VAC
50/60 Hz
50/60 Hz
47–63 Hz
47–63 Hz
6A/3A
3.5A/1.75
Typical 270 btu/hr
(68 kg-cal/hr)
Maximum
Maximum 1025 btu/hr
(258 kg-cal/hr)
Variable speed fan
X
<4W
<3W
X
X
Page 19