HP ProCurve Switch 8100fl Series
Specifications
Included accessories
Ports
Power supplies
Physical characteristics
Dimensions
Weight
Memory and processor
Fabric
Interface Module
Management Module
Mounting
Performance
Latency
Throughput
Routing/Switching capacity
Routing table size
Environment
Operating temperature
Operating relative humidity
Non-operating/Storage temperature
Non-operating/Storage relative humidity
Altitude
Electrical characteristics
Maximum heat dissipation
HP ProCurve Switch 8108fl (J8727A)
1 HP ProCurve Switch fl Redundant Management Module (J8731A)
1 HP ProCurve 8108fl Redundant Switch Fabric Module (J8729A)
1 HP ProCurve Switch fl Redundant Power Supply (J8732A)
8 open module slots
Supports a maximum of 80 auto-sensing 100/1000 ports or 16
10-GbE ports or 80 mini-GBICs, or a combination
includes: 1 x J8732A
2 open power supply slots
21.5(d) x 17.3(w) x 22.7(h) in. (54.61 x 43.94 x 57.66 cm) (13U
height)
219.7 lb. (99.66 kg)1 8-slot chassis, 2 switch fabric modules, 2
management modules, 2 fan trays, 3 power supplies, 8 internal
modules, Fully loaded
PowerPC IBM405 @ 266 MHz, 16 MB flash, 16 MB SRAM, 256 MB
SDRAM
PowerPC IBM405 @ 266 MHz, 16 MB flash, 256 MB SDRAM; packet
buffer size: 128 MB RL-DRAM per module
PowerPC MPC7410 @ 400 MHz, 16 MB flash, 512 MB compact
flash, 1 GB SDRAM
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet
(hardware included); horizontal surface mounting only. Requires 2 or
more persons or lift-jack assistance.
< 25 µs (FIFO 64-byte packets)
up to 119 million pps
160 Gbps
100000 entries
41ºF to 104ºF (5ºC to 40ºC)
15% to 80% @ 104ºF (40ºC), non-condensing
-40ºF to 158ºF (-40ºC to 70ºC)
0% to 90% @ 149ºF (65ºC), non-condensing
up to 15000 ft. (4.57 km)
5119 BTU/hr (5401 kJ/hr)
HP ProCurve Switch 8116fl (J8728A)
1 HP ProCurve Switch fl Redundant Management Module (J8731A)
1 HP ProCurve 8116fl Redundant Switch Fabric Module (J8730A)
2 HP ProCurve Switch fl Redundant Power Supply (J8732A)
16 open module slots
Supports a maximum of 160 auto-sensing 100/1000 ports or 32
10-GbE ports or 160 mini-GBICs, or a combination
includes: 2 x J8732A
1 open power supply slots
21.5(d) x 17.3(w) x 34.8(h) in. (54.61 x 43.94 x 88.39 cm) (20U
height)
340 lb. (154.22 kg)1 16-slot chassis, 2 switch fabric modules, 2
management modules, 2 fan trays, 3 power supplies, 16 internal
modules, Fully loaded
PowerPC IBM405 @ 266 MHz, 16 MB flash MB, 16 MB SRAM, 256
MB SDRAM
PowerPC IBM405 @ 266 MHz, 16 MB flash, 256 MB SDRAM; packet
buffer size: 128 MB RL-DRAM per module
PowerPC MPC7410 @ 400 MHz, 16 MB flash, 512 MB compact
flash, 1 GB SDRAM
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet
(hardware included); horizontal surface mounting only. Requires 2 or
more persons or lift-jack assistance.
< 25 µs (FIFO 64-byte packets)
up to 238 million pps
320 Gbps
100000 entries
41ºF to 104ºF (5ºC to 40ºC)
15% to 80% @ 104ºF (40ºC), non-condensing
-40ºF to 158ºF (-40ºC to 70ºC)
0% to 90% @ 149ºF (65ºC), non-condensing
up to 15000 ft. (4.57 km)
10238 BTU/hr (10801 kJ/hr)
3
Need help?
Do you have a question about the ProCurve 8108 and is the answer not in the manual?
Questions and answers