Cs-A12Gk Cu-A12Gk - Panasonic CS-A7GKD Service Manual

Table of Contents

Advertisement

8.2.

CS-A12GK CU-A12GK

Resistance of Indoor Fan Motor Windings
MODEL
CONNECTION
BLUE-YELLOW
YELLOW-RED
Note: Resistance at 25°C of ambient temperature.
Resistance of Outdoor Fan Motor Windings
MODEL
CONNECTION
BLUE-YELLOW
YELLOW-RED
Note: Resistance at 25°C of ambient temperature.
CS-A12GK
CWA921373
390.0 Ω
394.0 Ω
CU-A12GK
CWA951117J
230 Ω
255 Ω
18
Resistance of Compressor Windings
MODEL
CONNECTION
C - R
C - S
Note: Resistance at 20°C of ambient temperature.
CU-A12GK
2KS206D5AF04
2.234 Ω
2.630 Ω