  • Page 3: Safety

    READ AND SAVE THESE INSTRUCTIONS Intended for domestic cooking only INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER. Register your range hood online at www.broan.ca WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: • Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
  • Page 4 WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. b) Always turn hood ON when cooking at high heat or when flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
  • Page 5: Operation

    Let the blower run for a few minutes to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and fresher. Operate the hood as follows: BNDD1 SERIES BLOWER BUTTON When blower is OFF, press this button to turn ON the blower at the last saved speed. If there was no speed saved, the blower will be set on LOW speed.
  • Page 6: Cleaning And Maintenance

    Cleaning and Maintenance Proper maintenance of the Range Hood will assure proper performance of the unit. MOTOR The motor is permanently lubricated and never needs oiling. If the motor bearings make excessive or unusual noise, replace the motor with the exact service motor. The fan blade should also be replaced.
  • Page 7: Installation

    For ADA compliance installation guidelines, please visit www.broan-nutone.com Recommended Tools and Accessories for Installation • Measuring tape • Phillips screwdriver no. 2 • Flat blade screwdriver (to open knockout holes) • Drill, 1/8” drill bit and 1½” hole saw (to mark holes for ducting and cut electrical access hole) •...
  • Page 8: Contents

    Contents Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the manufacturer. Make sure that the following items are included: IND INSIDE OF HOOD (1) 3¼” 10” (2) G REASE ILTERS AMPER ASSEMBLY EZ1 C OMPONENTS...
  • Page 9: Prepare The Hood

    Prepare the Hood 1 ] If present, remove all protective polyfilm from the hood and/or parts.  2 ] Using the finger cup, remove the grease filters from the hood by pushing down and tilting  filters out 3 ] Remove the EZ1 brackets from inside the hood by cutting off the tie wrap. Remove both screws holding the damper assembly to the hood.
  • Page 10 5 ] Remove 2 screws from top of hood (see illustration below). Keep the screws for further use. SCREWS 6 ] Remove the Electrical Power Cable Knockout from top (vertical wiring) or back (horizontal wiring) of hood. Install an appropriate strain relief, 1/2” diameter (not included). ELECTRICAL POWER CABLE KNOCKOUT...
  • Page 11 DUCTED INSTALLATION ONLY 8 ] Remove the 3¼” x 10” vertical, 3¼” x 10” horizontal, or 7-inch round knockout plate as appropriate for your ducting method (see F 1 A and 1 B). IGURES IGURE IGURE 7” ROUND KNOCKOUT PLATE ( ALSO REMOVE VERTICAL KNOCKOUT PLATE 3¼”...
  • Page 12: Prepare The Hood Location

    Prepare the Hood Location NOTE: Before starting installation, read all the steps of these instructions. Use the illustration below to identify your kitchen cabinet type. FRAMED CABINET FRAMELESS CABINET This manual covers 2 kinds of installation: the standard (without EZ1 brackets) and the EZ1 one-person installation system (using included template and brackets).
  • Page 13 4 ] Drill a 1/8” dia. pilot hole for house wiring, at A location on template. 5 ] Use a sharp pencil or 1/8” drill bit to mark the locations for the appropriate duct access holes (16 locations for 7” round duct, or 4 corner locations for rectangular duct). Remove the template.
  • Page 14 FRAMELESS CABINET Refer to the marking on brackets to determine the correct installation side and orientation. 7/64”  Align the corresponding bracket to the cabinet side, while placing rear end of bracket against the wall. Draw a line on the outer edge of the bracket (as shown). ...
  • Page 15: Install The Hood (Ez1 Bracket)

    Install the Hood (EZ1 Bracket) OTE: The following procedure applies to both framed or frameless cabinet installations. 1 ] Run house power cable between service panel and hood location. 2 ] There are 2 pairs of recessed holes on each side of the top of the hood (on rear: A and B, on front C and D on illustration below);...
  • Page 16 7 ] For framed cabinet, secure the hood to the EZ1 brackets using 4 no. 8-18 x 1/2” metal screws (included in parts bag). Insert 2 screws per side, in the slots (as shown in insets on illustration below). 8 ] For frameless cabinet, secure the hood to the cabinet using 4 no. 8 x 5/8” round head wood screws (included in parts bag).
  • Page 17: Standard Installation

    Standard Installation (without EZ1 brackets) 1 ] Use the proper diagram below for placement of ductwork and electrical cutout in cabinet or wall. For a non-ducted installation, DO NOT cut a duct access hole, only cut the hole for electrical wiring. 3¼"...
  • Page 18: Install The Hood (Standard Installation)

    Install the Hood (Standard Installation) 1 ] Run the house power cable between service panel and hood location. Run the house power cable into the hood through the strain relief previously installed in step 6 on page 10. 2 ] Hang hood from 4 mounting screws previously installed. Slide hood back towards the wall until mounting screw heads are engaged in the narrow end of keyhole slots in top of hood.
  • Page 19: Connect The Wiring

    Connect the Wiring WARNING Risk of electric shock. Electrical wiring must be done by qualifi ed personnel in accordance with all applicable codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally.
  • Page 20: Wiring Diagram

    BNDD1 SERIES...
  • Page 21: Service Parts

    BNDD1 SERIES          UANTITY ART NO ESCRIPTION HITE TAINLESS 24" 30" 24" 30" S97020030 ECIRCULATION COVER PLATE HITE INCLUDING SCREWS S97020031 ECIRCULATION COVER PLATE TAINLESS STEEL INCL SCREWS S97020534 3¼” 10” D...