b. If the walking belt has shifted to the right, first remove the key
and UNPLUG THE POWER CORD. Using the allen wrench, turn
the left adjustment bolt counterclockwise 1/4 of a turn. Plug in
the power cord, insert the key and run the treadmill for a few
minutes. Repeat until the walking belt is centered.
5. SYMPTOM: THE HEART RATE MONITOR DOES NOT FUNCTION PROPERLY
a. If the heart rate monitor does not function properly, refer to HEART RATE MONITOR TROUBLE-
SHOOTING on page 6.
b. If the heart rate monitor still does not function properly, the battery should be
changed. To replace the battery, locate the battery cover on the back of the sen-
sor unit. Insert a coin into the slot in the cover and turn the cover counterclock-
wise to the "open" position. Remove the cover.
Remove the old battery from the sensor unit. Insert a new battery, making sure
that the writing is on top. In addition, make sure that the rubber gasket is in
place in the sensor unit. Replace the battery cover and turn it to the closed posi-
tion.
6. SYMPTOM: AN ERROR CODE (E1, E20, E21, E22, E23, OR E24) APPEARS ON THE CONSOLE
a. If an error code appears, remove the key from the console, wait for a moment, and then reinsert it. If the
error code appears again, call our Customer Service Department. Do not use the treadmill until the problem
is corrected.
b
Battery
Rubber
Gasket