Panasonic PT-VX41U Operating Instructions Manual page 75

Table of Contents

Advertisement

2 )
Replace the air filter units.
Put new air filter units back into the position. Make sure that the filters are fully inserted to the projector.
z
Resetting the Filter Counter
J
Be sure to reset the Filter counter after replacing the air filter units. (
Attention
Turn off the power before you replace the air filter units.
z
When attaching the air filter units, make sure that the projector is stable, and work in an environment that is
z
safe, even in the event of the air filter units dropping.
Do not operate the projector with the filters removed. Dust may accumulate on the optical elements degrading
z
picture quality.
Do not put anything into the air vents. Doing so may result in malfunction of the projector.
z
Do not wash the filters with water or any other liquid matter. Otherwise the filters may be damaged.
z
The air filter unit to be replaced should be an unused product.
z
After replacing the air filter, reset the filter counter. Otherwise, the power of the projector may be turned off for
z
safety.
Attaching the Air Filter Cover to the Projector
J
The supplied filter cover is designed for preventing dust accumulation on the filter when mounting the projector on
the ceiling.
1 )
Turn over the projector.
2 )
Remove the air filter cover (bottom).
3 )
Attaching the air filter cover to the projector.
Push the cover as the picture shown.
z
4 )
Attach the projector to the ceiling mount
in accordance with the instruction
manuals which come with the ceiling
mount.
Attention
Please keep the air filter cover (bottom) for later use.
z
If the Projector Mount Base ET-PKV100B is applied, the supplied air filter cover is unnecessary.
z
page 57" Filter counter reset")
Æ
To Ceiling Mount
(
Æ
page 74)
Replacement
Air Filter
Cover
(supplied)
Projector
ENGLISH -
75

Advertisement

Table of Contents
loading

Table of Contents