Panasonic PT-VX41U Operating Instructions Manual page 64

Table of Contents

Advertisement

Network
Error information page
J
If [Error (Detail)] is displayed in the self-diagnosis information display column on the [Projector status] screen,
click the part to display the details of the error.
Depending on the nature of the error, the projector may be placed in the standby mode for its own protection.
Parameter
FAN
INTAKE AIR TEMPERATURE
EXHAUST AIR TEMPERATURE
OPTICS MODULE TEMPERATURE
LAMP REMAIN TIME
LAMP STATUS
64
- ENGLISH
When [FAILED] has appeared for an item
Trouble has occurred in the fan or its drive circuit. Consult your dealer.
Intake air temperature is high. It could be because it is used in an environment of high
temperature such as close to a heating device, etc., the air intake is blocked, or the air
filter is clogged.
Exhaust air temperature is high. Exhaust may be blocked, or high altitude mode may
be set wrong.
Optics module temperature is high.
The lamp runtime has exceeded the prescribed cumulative time, and it is now time to
replace the lamp.
The lamp has failed to light.
Wait a short while for the lamp to cool off, and then turn on the power.
OK:
Normal operation
FAILED:
Occurrence of trouble
WARNING: Abnormal condition
Description

Advertisement

Table of Contents
loading

Table of Contents