Calibrating Media Sensor By Diagnostic Tool; Auto Calibration - zenpert 4T520P Series User Manual

Thermal transfer/direct thermal bar code printer
Table of Contents

Advertisement

5.3 Calibrating Media Sensor by Diagnostic Tool

5.3.1 Auto Calibration

1. Make sure the media is already installed and print head mechanism is closed. (Please refer
to section 3.3.)
Note:
The media sensor position is moveable. Please make sure the gap or black mark is
at the location where media gap/black mark will pass through for sensing.
2. Turn on the printer power switch.
3. Open Diagnostic tool and set interface. (The default setting is USB.)
The default interface setting is
USB interface. If USB interface
is connected with printer, no
other settings need to be
changed in the interface field.
4. Click the "Calibrate Sensor" button.
5. Select the media type and click the "Calibrate" button.