Installation Space Requirements

• Where a wall or other obstacle is in the path of the outdoor unit's intake or exhaust airflow, follow the installation space
requirements below.
• For any of the below installation patterns, the wall height on the outlet side should be 47-1/4 inch (1200mm) or less.
09/12 class
Wall facing one side
More than
1-15/16 (50)
Walls facing three sides
More than
1-15/16 (50)
15/18 class
Wall facing one side
More than
3-15/16 (100)
Walls facing three sides
More than
1-15/16 (50)

Outdoor Unit Installation

1.

Installing the outdoor unit

1) When installing the outdoor unit, refer to "Precautions for Selecting a Location" and the "Outdoor Unit Installation Diagram".
2) If drain work is necessary, follow the procedures on the next page.
5
More than
3-15/16 (100)
47-1/4
(1200)
or less
Side view
More than 5-7/8 (150)
More than
11-13/16 (300)
Top view
More than
13-3/4 (350)
47-1/4
(1200)
or less
Side view
More than 3-15/16 (100)
More than
13-3/4 (350)
Top view
Walls facing two sides
More than
3-15/16 (100)
More than
1-15/16 (50)
unit: inch (mm)
Walls facing two sides
More than
3-15/16 (100)
More than
1-15/16 (50)
unit: inch (mm)
More than
5-7/8 (150)
More than
1-15/16 (50)
Top view
More than
13-3/4 (350)
More than
1-15/16 (50)
Top view