Option 58. Msp Audio Flags; Option 59. Nicam Threshold; Option 60. Power Delay Time - Sharp 32LW-92H Service Manual

Pal i system colour television
Hide thumbs Also See for 32LW-92H:
Table of Contents

Advertisement

MSP Stereo/Mono Threshold

Option 58. MSP Audio Flags

B7: b7 =
x
B6: b6 =
x
B5: b5 =
x
B4: Trs =
note 1
B3: Trb =
note 1
B2: Bbe =
note 1
B1: Spa =
note 1
B0: Avl =
note 1
note 1 :
Defines whether the feature is toggled ON or OFF in the menu and stored.
0
: OFF
1
: ON

Option 59. NICAM Threshold

MSP NICAM Threshold

Option 60. Power Delay Time

B7: NZ =
x
B6: HM =
x
B5: L5 =
note 3
B4: L4 =
note 3
B3: L3 =
note 3
B2: L2 =
note 3
B1: L1 =
note 3
B0: L0 =
note 3
note 3:
L7 L6 L5 L4 L3 L2 L1 L0
Default Value :
x
1000 MSEC
= 1SN
AK45 Service Manual
0 0 0 1 1 0 0 1
b7 b6 b5 b4 b3 b2 b1 b0
0 1 1 0 0 1 0 0
x
1
1
0
0
0
0
42
17/12/2007