All safety guidelines, product descriptions, illustrations, and specifications found throughout this manual were in effect at the time the manual was released for printing. It should be noted; REED RESERVES THE RIGHT TO MAKE CHANGES IN DESIGN OR TO MAKE ADDITIONS TO OR IMPROVEMENTS IN THE PRODUCT WITHOUT IMPOSING ANY OBLIGATIONS UPON ITSELF TO INSTALL THEM ON PRODUCTS PREVIOUSLY MANUFACTURED.
OPERATION and MAINTENANCE (909)287-2100 WARRANTY REED warrants each new Concrete equipment A,B, and C Series to be free of defects in material and workmanship under normal use and service for a period as follows: CONCRETE PUMP • 1 year or 1200 operating hours, whichever occurs first •...
Failure Date: Repair Date: Do not send part(s) until requested by REED or until claim is approved. All parts requested to be returned must have a Return Authorization Number provided by REED and shipping freight prepaid. Parts must ship within 30 days from REED request.
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 SAFETY Everyone involved with the operation, maintenance, inspection, and repair of the concrete pump MUST READ and UNDERSTAND this manual and the accompanying Safety Manual. SAFETY ALERT SYMBOLS AND SIGNAL WORDS The following safety alert symbols, signals, and explanations are intended to warn the operator of hazardous and potentially hazardous situations.
OPERATION and MAINTENANCE (909)287-2100 LOCKOUT / TAGOUT The Lockout/Tagout procedure applies to all REED concrete placing equipment. Before performing any maintenance and/or repair on equipment. 1. Remove keys lock-out signage must be posted to indicate machine is currently under Lockout/Tagout.
Only Operate, Maintain, Inspect, and Repair In Accordance with This Operation Manual and the Safety Manual Performance and Safety Features Must Never Be Altered, Disconnected, or Removed Contact REED Technical Support and Service When Assistance Is Required Rev 1.2 7 of 80...
Association (CPMA) for your protection. They are placed at appropriate areas on the concrete pump to be constant warnings of dangers. Know and adhere to the information they provide. Contact REED Customer Service for complimentary replacements of safety decals, shipping charges may apply.
Page 10
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 DO NOT OPERATE MACHINE WITHOUT ALL GRATES IN PLACE Rev 1.2 9 of 80...
Page 11
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 Rev 1.2 10 of 80...
Page 12
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 Rev 1.2 11 of 80...
Page 13
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 DECALS PLACED NEAR HOPPER GRATE AREA Rev 1.2 12 of 80...
Page 14
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 DECALS PLACED NEAR WATERBOX AREA DECALS PLACED NEAR OUTRIGGER CONTROL AREA Rev 1.2 13 of 80...
Page 15
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 DECALS PLACED ON SIDE PANEL AREA Rev 1.2 14 of 80...
Page 16
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 Rev 1.2 15 of 80...
Page 17
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 Rev 1.2 16 of 80...
Page 18
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 PRODUCT DESCRIPTION The operation of the concrete pump encompasses the use of hydraulic and electrical systems. The concrete pump is designed to safely pump wet concrete through a delivery system of pipes and hoses within its published ratings and specifications. Stability of the concrete pump during operation is provided by the outriggers and front jack.
Page 19
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 The power for operation of the concrete pump is provided by the engine, which drives the hydraulic pumps. All functions for operation of the concrete pump can be accomplished from the local controls mounted on the side of the unit. Optional hand-held cable or radio remotes enable the pump to be operated away from a remote distance.
Page 20
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 solenoid operation. Its purpose is to direct the flow of oil from the main hydraulic pump to one or the other To energize the pump circuit, use the RPM button to set the engine speed at maximum RPM.
Page 21
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 MAIN PUMP CIRCUIT OPERATIONAL SEQUENCE It can be noted in the schematic and the diagram below that the main pressure and flow is only directed to one side of the hydraulic drive cylinder. In this instance, it is directed to the head side or piston side of the double acting drive cylinder.
Page 22
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 is accomplished by use of the check valves installed on both cylinders. By holding the STROKE CHANGE switch, you have interrupted the cycle and are forcing more oil into the head side of the extending cylinder. Since that cavity is full, pressure is built up in the rod side of the fully retracted cylinder, which unseats the head-side check valve and forces the excess oil out of the slave loop and back to the tank.
Page 23
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 B-SERIES HYD FILTER TANK CLEANOUT D08 VALVE MANUAL VOLUME CONTROL S-TUBE DRIVE CYLINDER MANAFOLD MANAFOLD Rev 1.2 22 of 80...
Page 24
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 C-SERIES TANK CLEANOUT D08 VALVE HYD FILTER S-TUBE MANAFOLD ACCUMULATOR Rev 1.2 23 of 80...
Page 25
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 S-TUBE CIRCUIT Since there is only one outlet for the pumping material, a means is required to transfer the material from the material cylinder to the outlet and into the delivery line. To accomplish this, an s-tube is installed in the hopper. Since there are two material cylinders and one s-tube, the s-tube must be shifted from one material cylinder to the other, whichever one is loaded with the pumping material.
Page 26
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 • SOLENOID VALVE CARTRIDGE There are two (2) of these cartridges used in the circuit. Both, which may be referred to as a dump valve, are designed into the circuit as SAFETY VALVES. Their purpose is to automatically relieve pressure from the shift circuit as commanded by the emergency stop circuit.
Page 27
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 S-TUBE CIRCUIT OPERATIONAL SEQUENCE In the operational sequence of the shift circuit with the engine at full RPM, the tandem pump is producing its rated displacement. The flow is going through the system and is being dumped or directed back to the tank thru the solenoid cartridges of the s-tube circuit manifold.
Page 28
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 AUXILIARY CIRCUIT The auxiliary circuit has been designed and installed for the purpose of operating the hydraulic function of the auxiliary equipment on the unit, primarily the agitator. This function is that of the agitator rotation for mixing the material in the hopper and feeding of the concrete cylinders.
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 OPERATION OPERATOR QUALIFICATIONS Everyone involved with the operation, maintenance, inspection, and repair of the concrete pump MUST READ and UNDERSTAND this operation manual and the accompanying Safety Manual. The following are a few general warnings for operator qualifications outlined in the Safety Manual.
Pump ( A B C Tier ver. Pump type Display serial # PLC program ver. MD4-5 Display (Reed p/n 88612) serial # PLC program Controller module MC42 Controller (Reed p/n 89613) serial # serial # Rev 1.2 30 of 80...
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 CONTROLS PLC MAIN CONTROLS A-SERIES 2. MAIN POWER SWITCH this is a three (3) position key switch. Turn-key to the ON position to power control box. Shut down power by turning key to OFF position. START position.
Page 34
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 CONTROL SWITCH (LOCAL/REMOTE) this is used to select the pump control location. Press button to LOCAL to enable operation of concrete pump for main stationary panel. Press button to REMOTE for operation using the remote control. STROKE-SWITCH Press button to test stroke change.
Page 35
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 PUMP VOLUME, this is to turn the pump volume up or down. Press button VOLUME UP to increase volume, and press button VOLUME DOWN to reduce volume. SCREEN NAVIGATION is to move UP and DOWN in screen menu. ENTER, is to select enter in screen menu.
Page 36
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 CONTROLS GASOLINE CONTROLS B-SERIES MAIN POWER SWITCH this is a three (3) position key switch. Turn-key to the ON position to power control box. Shut down power by turning key to OFF position. START position. To start engine turn to start position and hold until engine starts.
Page 37
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 GASOLINE CONTROLS B-SERIES CONTROL SWITCH (LOCAL/REMOTE) this is used to select the pump control location. Press toggle to LOCAL to enable operation of concrete pump for main stationary panel. Press toggle to REMOTE for operation using the remote control.
Page 38
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 GASOLINE CONTROLS B-SERIES 1. PUMP VOLUME, this is to turn the pump volume up or down. Press toggle VOLUME UP to increase volume, and press toggle VOLUME DOWN to reduce volume. 2. VIBRATOR (if equipped-HOPPER OPTION) controls vibrator activation.
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 PRODUCT DESCRIPTION The operation of the concrete equipment encompasses the use of hydraulic and electrical systems. This Concrete Pump is designed to safely mix wet concrete or material within its published ratings and specifications. Stability of the concrete pump during operation is provided by the ( ) outrigger legs and the front jack that can be raised or lowered from the concrete pump, to accommodate terrain.
Page 40
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 PRODUCT DESCRIPTION The operation of the concrete equipment encompasses the use of hydraulic and electrical systems. This Concrete Pump is designed to safely mix wet concrete or material within its published ratings and specifications. Stability of the concrete pump during operation is provided by the ( ) outrigger legs and the front jack that can be raised or lowered from the concrete pump, to accommodate terrain.
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 CONTROLS PLC MAIN CONTROLS B, C-SERIES EMERGENCY STOP This push/pull emergency switch is used to shut down the pump in an emergency by disabling the hydraulic systems. It does not shut the engine or motor off. Depress PUSH knob in to STOP operation. PULL knob out to REACTIVATE system.
Page 42
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 PLC MAIN CONTROLS B, C-SERIES MAIN POWER KEY MAIN DIGITAL DISPLAY this is a three (3) this is where all position key switch. Turnkey to the ON position the pumping statues are displayed. to power control box. Shut down power by turning key to OFF position.
Page 43
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 Rev 1.2 42 of 80...
Page 44
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 Rev 1.2 43 of 80...
Page 45
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 Rev 1.2 44 of 80...
Page 46
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 Rev 1.2 45 of 80...
Page 47
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 Rev 1.2 46 of 80...
Page 48
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 Rev 1.2 47 of 80...
Page 49
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 Rev 1.2 48 of 80...
Page 50
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 NOTE: C-SERIES GAUGES PUMP or DRIVE CYLINDER GAUGE indicates the hydraulic pressure requirement of the pumping cylinders to push material. Gauge reading varies depending upon many circumstances such as: material slump, material line type, size and length, vertical, uphill, downhill or horizontal placement, pumping speed, etc.
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 JOBSITE SET-UP Refer to the Safety Manual for set-up safety precautions not limited to the following guidelines: Ensure Machine Can Be Safely Operated in Set-Up Location Away from Hazards and Dangers Away from Slopes and Excavations Position Machine on As Solid and Level Ground As Possible Adjust height of Machine and remove Leg pins Secure Machine Positions with Leg Pins and Locks...
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 PREPARING FOR SYSTEM START-UP Everyone involved with the operation, maintenance, inspection, and repair of the concrete pump MUST READ and UNDERSTANDS this manual and the Safety Manual. Refer to the Safety Manual for pumping and blockages safety precautions not limited to the following guidelines: Perform Required Inspection, Lubrication, and Maintenance Before, During, and After Pumping Operations...
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 OPERATION OF CONTROLS A-SERIES TIER-4 THE HOPPER GRATE MUST BE CLOSED (There is a safety interlock that guards against the opening of the mixer grate). SYSTEM START-UP Turn Pump ON Only When Hopper Is Full of Concrete Ensure the following conditions are met before activating pump: o PUMP Switch Is “OFF”...
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 OPERATION OF CONTROLS B-SERIES GASOLINE THE HOPPER GRATE MUST BE CLOSED (There is a safety interlock that guards against the opening of the mixer grate). SYSTEM START-UP Turn Pump ON Only When Hopper Is Full of Concrete Ensure the following conditions are met before activating pump: o PUMP Switch Is “OFF”...
Page 55
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 OPERATION OF CONTROLS B&C-SERIES TIER-4 THE HOPPER GRATE MUST BE CLOSED (There is a safety interlock that guards against the opening of the mixer grate. SYSTEM START-UP Turn Pump ON Only When Hopper Is Full of Concrete Ensure the following conditions are met before activating pump: o PUMP Switch Is “OFF”...
Engine Manufacturer Maintenance Schedule Must Be Followed Read Engine Manufacturer Manual REED has provided only general guidelines regarding engine maintenance and will not cover engine warranty claims. Rev 1.2 55 of 80...
Page 57
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 MAINTENANCE Hydraulic Pressure in All Systems Must Be ZERO Before and During Any Maintenance Procedures Engine Must Be Turned OFF and Lockout / Tagout Procedures Must Be Followed Before and During Any Maintenance Procedures Rev 1.2 56 of 80...
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 GENERAL MAINTENANCE AREAS Perform scheduled inspections to identify and detect any potential problems. The list presented should be inspected and checked on a regular basis and is a recommended minimum. TRAILER • Frame integrity, visually check welds, cracks •...
Page 59
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 Perform scheduled inspections to identify and detect any potential problems. The list presented should be inspected and checked on a regular basis and is a recommended minimum. MAIN CONTROLS • Control box in good condition, sealed, not damaged •...
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 WHEEL AND TIRE SAFTEY CAUTION YOU MUST FOLLOW THE MAINTENANCE PROCEDURES TO PREVENT DAMAGE TO IMPORTANT STRUCTURAL COMPONENTS. DAMAGE TO CERTAIN STRUCTURAL COMPONENTS SUCH AS WHEEL BEARINGS CAN CAUSE THE WHEEL END TO COME OFF OF THE AXLE. LOSS OF A WHEEL END WHILE THE TRAILER IS MOVING CAN CAUSE YOU TO LOSS CONTROL AND LEAD TO AN ACCIDENT, WHICH CAN RESULT IN SERIOUS INJURY OR DEATH.
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 TRAILER RECOMMENDED MAINTENANCE BRAKE ADJUSTMENT PROCEDURE 1. Make sure your trailer is on level surface and is free of any potentially dangerous items. 2. Jack up the trailer and secure with jack stands. Supporting the trailer until the tire and wheel are clear of the ground surface.
Page 62
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 WHEEL AND TIRE MAINTENANCE Your trailer manufacture has specified the wheel and tires to be used. It is very important that you do not make changes that may alter the recommended size or load capacities. Any deviations, however slight or unnoticeable, may cause damage or be dangerous to operate.
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 LUBRICATION Rapid wear and possible shutdown will result if the unit is operated with inadequate lubrication. Follow the recommendations stated herein, and if needed increase the application of lubricants above these recommendations when the equipment is subject to heavy usage.
Page 64
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 LUBRICATION POINTS The following graphics are for REFERENCE ONLY. IF EQUIPPED WITH DUAL (2) HYDRAULIC SHIFT CYLINDERS, RELIEVE SHIFT CIRCUIT HYDRAULIC PRESSURE TO PROPERLY GREASE HYDRAULIC SHIFT CYLINDERS AND BELL CRANK LUBRICATION POINTS Rev 1.2 63 of 80...
Page 65
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 LUBRICATION POINTS S-TUBE OUTLET GREASE POINTS AGITATOR GREASE POINTS HYDRAULIC MOTOR SIDE GREASE POINTS BEARING SIDE GREASE POINTS Rev 1.2 64 of 80...
Page 66
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 HYDRAULIC SYSTEM Hydraulic pumps are used to supply the flow of oil necessary to operate actuators of the concrete pump. Contamination of the Oil Is the Leading Contributor to System Malfunctions Extreme care must be exercised to prevent contaminants from entering the system. Always cap or plug open ports and hydraulic lines.
Page 67
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 HYDRAULIC SYSTEM MAINTENANCE ITEM DESCRIPTIONS FLUID Check fluid level and oil clarity daily with sight gauge provided. Maintain level at full mark. Add hydraulic oil through the return filter fill port when necessary. TANK BREATHER Clean every 50 hours of operation.
Page 68
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 ADDING HYDRAULIC FLUID There are a few common methods for filling the hydraulic tank as described below. Exercise extreme care when adding fluid to the hydraulic tank to avoid contamination. • To prevent any dirt or water from entering the hydraulic tank, thoroughly clean area around the return filter fill port plug, the vented fill cap or the inspection cover.
Page 69
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 SERVICING FLUSH BOX When servicing parts in flush box, drain old oil using plug underneath flush box. Clean out debris, fill with clean hydraulic fluid 7” as shown below. HYDRAULIC CYLINDER MATIRIAL 7” CONCRETE CYLINDER PLUG Rev 1.2 68 of 80...
Page 70
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 FILTER SERVICING Hydraulic filters provide a means of continuous hydraulic fluid filtration to prevent recirculation of contamination which will cause rapid wear and component breakdown. A filter that is equipped with a condition indicator gauge should be checked daily and the element changed when indicated to do so.
Page 71
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 NEW HOUSING Do Not Use Cloth for Straining Fluid Lint Is a Contaminant Harmful to the Hydraulic System OLD HOUSING FILTER ELEMENT O-RING Rev 1.2 70 of 80...
Page 72
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 To change the filter elements: 1. Shut off machine. 2. VERIFY PRESSURES IN ALL CIRCUITS READ ZERO! 3. Wipe clean any dirt and grime from area surrounding filter housing 4. Loosen the filter cover plate bolts 5.
COMPONENT REPLACEMENT When parts are worn, do not delay in replacement. Continued usage with worn parts may lead to damage of other components. Please contact the REED Service Department or your local dealer for technical support. Rev 1.2 72 of 80...
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 PUMP MAINTENANCE SCHEDULE AND CHECKLISTS Providing a maintenance schedule defined specifically by run hours or yardage pumped serves only as a general guideline given the large amount of variables a unit might be subject to, such as weather and ambient temperature conditions, jobsite conditions, material differences of mix design, the load burden the unit is typically subject to, i.e.
Page 75
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 INITIAL 50 HOUR MAINTENANCE CHECKLIST Actual Hours Date # Maintenance Description Initials Change engine oil and filters (see engine manufacturer maintenance schedule for additional requirements) IF REQUIRED Additional Notes: Change hydraulic oil filters Inspect hydraulic hoses and fittings for any signs of external wear or damage Additional Notes: Rev 1.2 74 of 80...
Page 76
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 EVERY 100 HOUR MAINTENANCE CHECKLIST Actual Hours Date Maintenance Description Initials Clean hydraulic tank breather Inspect all structural components (check frame, hopper, and other structural members for any damage) Additional Notes: Additional Notes: Check coolers and radiators for dirt or debris. Clean as necessary Check condition of engine drive belts.
Page 77
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 EVERY 250 HOUR MAINTENANCE CHECKLIST Actual Hours Date # Maintenance Description Initials Change hydraulic filters (or change more frequently as indicated by indicator gauge on filter) Additional Notes: Check that all electrical wires, cables, terminals, plugs are in good condition Additional Notes: Change engine oil and filters (see engine manufacturer guide for all engine requirements) IF REQUIRED...
Page 78
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 EVERY 250 HOUR MAINTENANCE CHECKLIST Actual Hours Date Maintenance Description Initials Control console in good condition Switch in good condition Additional Notes: Rev 1.2 77 of 80...
Page 79
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 EVERY 500 HOUR MAINTENANCE CHECKLIST Actual Hours Date Maintenance Description Initials Inspect hydraulic hoses and fittings for any signs of external wear or damage Additional Notes: Inspect all wear parts and change as necessary (excessive wear may cause inefficient performance and/or shutdown of operation) Additional Notes: Change hydraulic fluid, clean the reservoir and the suction strainers within...
Page 80
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 EVERY 500 HOUR MAINTENANCE CHECKLIST Actual Hours Date ADDITIONAL GENERAL NOTES: Rev 1.2 79 of 80...
Page 100
CONTROL PANEL ERROR CODES The control panel screen has additional parameters to display pump information. PUMP STROKES – Resettable stroke counter that ticks up as machine is pumping. To reset press and hold STROKE CHANGE switch while pump is off. PUMP STROKE RATE (SPM) –...
Page 102
PowerView Error Messages 0710170 Diagnostic Trouble Codes Text Translations provided by: 12-13-07 PowerView Model PV101 software version Murphy 1.00.06 Section 78 PowerView Model PV100 software version Murphy 2.09 Note: This list represents text descriptions for faults supported by the PowerView and does not necessarily comply with SAE J1939.
Page 103
PowerView Error Messages Diagnostic Trouble Codes Text Translations provided by: PowerView Model PV101 software version Murphy 1.00.06 PowerView Model PV100 software version Murphy 2.09 Description ENG COOL TEMP HIGH LOW COOLANT LEVEL RETARDER OIL TEMPERATURE ABOVE NORMAL KEYSWITCH INTERMITTENT KEYSWITCH CIRCUIT PROBLEM INTERNAL TEMPERATURE FUEL TEMP HIGH FUEL TEMPERATURE SENSOR DEFECTIVE...
Page 104
PowerView Error Messages Diagnostic Trouble Codes Text Translations provided by: PowerView Model PV101 software version Murphy 1.00.06 PowerView Model PV100 software version Murphy 2.09 Description TIMING (CRANK) SENSOR TIMING SIGNAL ERROR TIMING (CRANK) SENSOR TIMING SIGNAL ERROR TIMING (CRANK) SENSOR TIMING SIGNAL ERROR CAN BUS FAILURE INJ CYLINDER1 CURRENT LESS THAN EXPECTED INJ CYLINDER1 CURRENT INCREASES TOO RAPIDLY...
Page 105
PowerView Error Messages Diagnostic Trouble Codes Text Translations provided by: PowerView Model PV101 software version Murphy 1.00.06 PowerView Model PV100 software version Murphy 2.09 Description EXT AUX ENG SHUTDOWN SWITCH ACTIVE ENG DERATE SWITCH ACTIVATED 1041 START SIGNAL MISSING 1041 START SIGNAL ALWAYS ACTIVE 1076 FUEL INJ PUMP CONT VALVE ERROR...
Page 106
TRAILER PLUG PINOUT OPEN NOT USED OPEN NOT USED #2 GREEN BLACK TAIL LIGHTS OPEN NOT USED OPEN NOT USED #2 GREEN TAIL LIGHTS #3 RED #1 BROWN #3 RED #1 BROWN LEFT TURN RIGHT TURN LEFT TURN RIGHT TURN &...
B50HPG 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 PARTS PUMPING TRAIN ASSEMBLY WATERBOX TOP VIEW WITH OUT AGITATOR ONLY DETAIL C DETAIL B DETAIL A 4, 5, ID # PART # PART DESCRIPTION QUANTITY 88012-2-10...
Page 110
B50HPG 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 PUMPING TRAIN ASSEMBLY CONTINUED DUAL SHIFT (OPTION) DETAIL G 300 FT-LB DETAIL F 280 FT-LB ID # PART # PART DESCRIPTION QUANTITY 86047 TIE ROD, 1" X 51½”...
B50HPG 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 5” OUTLET SEAL KIT INSTALLATION VIEW A GROOVE IN SEAL ID # PART # PART DESCRIPTION QUANTITY 79895 SEAL KIT 77762 O-RING-#257 BUNA 90 77761 O-RING-#264 BUNA 90...
B50HPG 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 DRIVE CYLINDER ASSEMBLY ID # PART # PART DESCRIPTION QUANTITY 86304-2 HYD CYLINDER GROUP 78961 CHECK VALVE-5K PSI O-RING 86748 FITTING-MB-MJ90-6-6 ELBOW, MB-MB90-6-6 86223HT HYDRAULIC CYLINDER 3.50 X 2.00 X 35.75...
B50HPG 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 DUAL SHIFT CYLINDER ASSEMBLY DETAIL E ID # PART # PART DESCRIPTION QUANTITY 86220HT SWING RAM-DUAL-2.50 X 5.75 STROKE 86220A-SK SEAL KIT B50G-V01 11 of 63...
B50HPG 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 DUAL SHIFT ASSEMBLY DETAIL E SPACE AS REQUIRED FOR PROPER S-TUBE 4 or 5 ALIGNMENT SPACE AS REQUIRED FOR PROPER S-TUBE 4 or 5 ALIGNMENT ID #...
B50HPG 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 HOPPER AGITATOR ASSEMBLY VIEW F DETAIL F ID # PART # PART DESCRIPTION QUANTITY 86322 AGITATOR ASSEMBLY 70211 FLANGE SEAL S/W 70212 SEAL REMIXER 85978 BEARING, BALL, PLAIN...
Page 120
B50HPG 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 AGITATOR ASSEMBLY CONTINUED DETAIL G NOTE* Install Grove as shown VIEW G ID # PART # PART DESCRIPTION QUANTITY GREASE FITTING, 1/8” NPT STRAIT 70219 REMIX SHAFT BUSHING...
B50HPG 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 CLEAN OUT-DOOR ASSEMBLY ID # PART # PART DESCRIPTION QUANTITY 86988 DOOR WELDMENT, CLEAN OUT 86559 BLOCK, CLEAN OUT DOOR, LH 86560 BLOCK, CLEAN OUT DOOR, RH 86922 SHOULDER SCREW 1"...
B50HPG 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 POWER TRAIN GROUP ENGINE ID # PART # PART DESCRIPTION QUANTITY 89838 POWER TRAIN ASSY 89832 ENGINE, FORD RSD862 89930 COOLING PACKAGE, FORD B50G-V01 18 of 63...
B50HPG 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 HYDRAULIC GROUP HYDRAULIC TANK ASSEMBLY ID # PART # PART DESCRIPTION QUANTITY 89836 HYD GR. B SER, KAW 85361 HYD TANK ASSY B-SERIES 85102 HYDRAULIC TANK WELDMENT...
Page 132
B50HPG 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 HYDRAULIC TANK ASSEMBLY CONTINUED ID # PART # PART DESCRIPTION QUANTITY 74509 GAUGE-SIGHT/TEMPERATURE 801025 DRAIN COCK, 1/4 NPT BG-12 ¾” SAE PLUG 70366 PRESSURE GAUGE, 3000 PSI/BAR...
B50HPG 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 TRAILER HARNESS AND BREAKAWAY ID # PART # PART DESCRIPTION QUANTITY 86533 TRAILER HARNESS- B-SERIES 77705 BREAK-AWAY KIT 5000 SERIES 86579 TRAILER PLUG 7C FLAT PI 72949...
B50HPG 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 CONTROL PANEL ID # PART # PART DESCRIPTION QUANTITY 89891 LED LIGHT, GREEN 89892 LED LIGHT, YELLOW 90482 CONTROL BOX, MACHINED 89840-D DECAL, MATTE LAM, B50G B50G-V01...
Page 144
B50HPG 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 CONTROL PANEL ID # PART # PART DESCRIPTION QUANTITY BW10205 TOGGLE SWITCH, ON-OFF-ON BW10361 BOOT TOGGLE SWITCH B50G-V01 38 of 63...
Page 145
B50HPG 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 CONTROL PANEL ID # PART # PART DESCRIPTION QUANTITY 89888 TOGGLE SWITCH ON-NONE-ON 90078 TOGGLE SWITCH, ON-NONE-ON, LOCKING 89887 TOGGLE SWITCH, ON-OFF-ON BW10361 BOOT TOGGLE SWITCH B50G-V01...
Page 146
B50HPG 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 CONTROL PANEL ID # PART # PART DESCRIPTION QUANTITY 89090-L ILLUMANATED E-STOP RING 89090 EMERGENCY STOP PUSH BUTTON B50G-V01 40 of 63...
Page 147
B50HPG 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 CONTROL PANEL ID # PART # PART DESCRIPTION QUANTITY 89108 KEY SWITCH 89108 INSERT 89107 CONNECTOR PLUG BW10147 B50G-V01 41 of 63...
Page 148
B50HPG 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 CONTROL PANEL ID # PART # PART DESCRIPTION QUANTITY 89995 DISPLAY, PV101 B50G-V01 42 of 63...
B50HPG 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 HOOD AND COVERS ID # PART # PART DESCRIPTION QUANTITY 89166 COVER TOP, B SER CUMMINS T4 PAINTED 87681 COVER FRONT, B SER CUM/ PAINTED 87647 GUSSET ENGINE COVER PAINTED...
B50HPG 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 OPTIONS 3 SPOOL CONTROL VALVE DETAIL A DETAIL B DETAIL D DETAIL C ID # PART # PART DESCRIPTION QUANTITY 85706 RELIEF, CARTRIDGE 74469 DETENT KIT, #11 WALVOIL VALVE...
B50HPG 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 OPTIONS 1 SPOOL AGITATOR VALVE DETAIL B DETAIL A DETAIL C ID # PART # PART DESCRIPTION QUANTITY 85706 RELIEF, CARTRIDGE 74469 DETENT KIT, #11 WALVOIL VALVE...
Page 165
B50HPG 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 OPTIONS AGITATOR GROUP CONTINUED ID # PART # PART DESCRIPTION QUANTITY 74584 VALVE, MANUAL-1 SPOOL 85657-016 HOSE, 8M2T-10FJX-10FJX45-20.00 85658-011 HOSE, 6M2T-6FJX-6FJX-21.00 85658-010 HOSE, 6M2T-6FJX-6FJX-20.00 FITTING, MB-MJ-10-6 85845...
B50HPG 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 AVAILABLE OPTIONS OUTRIGGER GROUP HYD OUTRIGGER OUTRIGGER/AGITATOR ELECTRIC OUTRIGGER AGITATOR GROUP STD/PADDLE OPTION/PADDLE HYD/AGITATOR/SINGLE HYD/AGITATOR/TRIPLE RADIO REMOTE AARCOMM 2-WAY RADIO W/STROKE COUNTER AND VOLUME INDICATOR (IF EQUIPPED) 50’...
Page 167
B50HPG 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 CARBIDE WEAR PARTS WEAR RING/CARBIDE WEAR PLATE/CARBIDE ELECTRIC VOLUME/FLOW CONTROL RADIO CONROL OF VOLUME (IF EQUIPPED) WATER PUMP WASH PUMP INSTALL WASH PUMP ASSY VIBRATOR KIT OLI KIT...
Page 168
B50HPG 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 TIRE & WHEEL ALUMINUM 9000 LB AUTO LUBE STEEL TUBING 12 PORT PLASTIC TUBING 12 PORT MANUAL LUBE BLOCK REMOTE EMERGENCY STOP B50G-V01 62 of 63...
Need help?
Do you have a question about the B50HPG and is the answer not in the manual?
Questions and answers