PCB Piezotronics 1630-04C Installation And Operating Manual

Strain gage load cell

Advertisement

Quick Links

Model 1630-04C
STRAIN GAGE LOAD CELL
Installation and Operating Manual
For assistance with the operation of this product,contact:
PCB Load & Torque, Inc.
Toll-free: 866-684-7107
24-hour SensorLine™: 716-684-0001
Fax: 248-888-8266
E-mail: LTInfo@pcbloadtorque.com
Web: www.pcbLoadTorque.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1630-04C and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PCB Piezotronics 1630-04C

  • Page 1 Model 1630-04C STRAIN GAGE LOAD CELL Installation and Operating Manual For assistance with the operation of this product,contact: PCB Load & Torque, Inc. Toll-free: 866-684-7107 24-hour SensorLine™: 716-684-0001 Fax: 248-888-8266 E-mail: LTInfo@pcbloadtorque.com Web: www.pcbLoadTorque.com...
  • Page 2 Returning Equipment – Following the equipment to PCB Piezotronics for these procedures will insure that your repair. User servicing or repair is not returned materials are handled in the recommended and, if attempted, may most expedient manner.
  • Page 3 PCB Piezotronics, Inc. Warranty – All equipment and repair 3425 Walden Ave. services provided by PCB Piezotronics, Depew, NY 14043 USA Inc. are covered by a limited warranty Toll-free: (800) 828-8840 against defective...
  • Page 4: Table Of Contents

    S-TYPE LOAD CELL OPERATION MANUAL TABLE OF CONTENTS 1.0 INTRODUCTION........................2 2.0 SAFETY PRECAUTIONS ....................2 3.0 OVERVIEW .......................... 2 3.1 Dimensions ............................2 4.0 MECHANICAL INSTALLATION ..................2 5.0 ELECTRICAL INSTALLATION ................... 2 5.1 Electrical Drawing / Western Regional Std..................3 5.2 Output Polarity ..........................3 5.3 Cable &...
  • Page 5: Introduction

    Table 1 - Full-Scale Capacities flat and parallel, with loads applied in-line with the sensor. Full-Scale Capacities Model (lbf) 5.0 ELECTRICAL INSTALLATION 1630-03C 1630-04C Table 4 - Electrical Connections 1630-06C 1112 1631-01C 2224 Electrical Connection: Pig-tailed, 10 ft, integrated cable...
  • Page 6: Electrical Drawing / Western Regional Std

    S-TYPE LOAD CELL OPERATION MANUAL 5.1 Electrical Drawing / Western Regional Std. The instrument or control system is grounded through its power cord. Ground loops and measuring system wiring may All load cells are wired following the Western Region result in unstable or noisy signals. Standard.
  • Page 7: Hysteresis

    S-TYPE LOAD CELL OPERATION MANUAL 6.1.2 Hysteresis 7.1 Resistor Value S-type load cells have a nominal 2.0 mV/V full scale output. The difference between the ascending and descending For a 350 ohm strain gage bridge the precision shunt resistor measured readings at 40% of full scale is used to calculate the is, 60,000 ohms ±...
  • Page 8: Trouble Shooting

    S-TYPE LOAD CELL OPERATION MANUAL Yearly calibrations are recommended to ensure that the unit’s Standard calibration certificates list five force points outputs match the factory specifications. ascending and one point descending. Additional data points are available at extra cost upon request. A 60 K ohm (±0.1%) shunt calibration resistor is supplied with each load cell 9.0 TROUBLE SHOOTING calibration.
  • Page 9 Model Number Revision: C STRAIN GAGE LOAD CELL 1630-04C ECN #: 41486 Performance ENGLISH OPTIONAL VERSIONS Measurement Range 100 lb 445 N Optional versions have identical specifications and accessories as listed for the standard model Sensitivity(± 10 %) 2 mV/V 2 mV/V except where noted below.

Table of Contents