Note: When using the left burner in Power Mode level 8.5 (1500W) or greater, the right burner
will not work. This is because the right burner requires a minimum of 400 watts to be available to
o
p
r e
t a
. e
T
h
e
c
o
m
When the left power level is in 8.5 or greater, press the "+" button of the right burner, it will
activate at the power level of "1.0" or press the "MENU" button of the right burner to switch to
Temperature Mode, the right burner will activate at the temperature setting of 300 °F. When the
left burner is in 8.5 (1500W) or greater, the temperature readout of right burner will fl ash in each
temperature setting, indicating the right burner does not work. To enable the Temperature Mode
of the right burner, please turn down the left power level to 8.0 or below. However, when using
the left burner in Power Mode level 8.0, the actual temperature of the right burner may take
longer to reach the setting temperature due to the power sharing with the left burner.
Both Power and Temperature Modes will be impacted by this safety feature. Selecting Power
Mode 8.5 or higher on the left burner will cause the right burner to go into standby and display
"0".
10-HOUR AUTOMATIC TIMER
The automatic timer may be used with either the Temperature or Power Mode. Press the "TIMER"
button to activate the timer. The TIMER portion of the LCD display will activate and 0:00 will appear
in the LCD READOUT DISPLAY. The :00 minutes portion of the readout will be blinking, indicating
the minutes can be set. Press the + or – button until the desired number of minutes appears. Wait
5 seconds and the 0: hours side of the readout will begin to blink. This indicates you may now set
the number of hours for the timer. Press the + or – key to set the number of hours. 5 seconds after
you have set the hours portion of the timer, the numbers will stop blinking and timing will start. If
you do not enter an amount of time into the AUTOMATIC TIMER within 10 seconds the feature will
shut off and the timer will not be set.
The + and – buttons can be "tapped" to increase or decrease the minutes/hours by 1 minute/1 hour
increments or they can be held down for rapid increase or decrease of time, as necessary.
The timer may be reset at any time during operation by pressing the "TIMER" button again. When
the timer has expired, the unit will "beep" and the cooktop will turn off.
AUTOMATIC SHUT OFF
Unless the timer has been set, this cooktop will shut down automatically in 120 minutes. This is a
safety feature in compliance with safety regulations.
NOTE: The cooktop unit will automatically shut off and "beep" if either:
• the wrong type of cookware is put on the cooktop
• no cookware is placed on the unit ("E0" will fl ash on the LCD screen) or
• the unit is turned on and the "MENU" button is not pressed
Copyright 2018-2022 Secura, Inc. All rights reserved.
b
n i
t a
o i
n
f o
1
5
0
0
W
p
PORTABLE DOUBLE INDUCTION COOKTOP
u l
s
4
0
0
W
w
o
u
d l
e
c x
www.duxtop.com / www.thesecura.com
e
e
d
h t
e
1
8
0
0
W
r
t a
n i
g
f
r o
h t
s i
c
o
o
k
o t
. p
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

9620ls

Table of Contents