Input BTU/Hr Maximum
Input BTU/Hr Minimum
KWH (Maximum)
KWH (Minimum)
Orifice
Air Shutter Opening
Gas Inlet Shutoff Valve (pipe)
NOTICE: Air shutter settings are factory minimum settings. Some venting configurations may require minor air shutter adjustments for
optimum performance.
HOMEOWNER REFERENCE INFORMATION
We recommend that you record the following information about your fireplace.
Model Number: _____________________________
Serial Number: _____________________________
Dealer Name: ______________________________
Notes: ______________________________________________________________________________
41380-0-0120
SPECIFICATIONS
DVC20IN(3,7)
Propane
Natural
19,500
20,500
15,000
14,500
5.37
5.95
4.2
4.2
1.30mm
#44
1/2 inch open
1/8 inch open
1/2 NPT
1/2 NPT
GAS SUPPLY PRESSURES
GAS TYPE
MAXIMUM
Natural
14
Propane
14
DVC26IN(3,7)
Propane
Natural
26,000
26,000
20,000
17,000
7.54
7.54
5.8
5.36
#53
#40
1/2 inch open
3/16 inch open
1/2 NPT
1/2 NPT
MINIMUM
MANIFOLD
4.5
3.5
11
10
Date purchased: ________________________
Location of fireplace: _____________________
Dealer Phone: _________________________
DVC28IN(3,7)
Propane
Natural
27,500
28,500
21,000
18,500
7.98
8.27
6.38
5.36
1.55mm
2.60mm
1/2
inch open
3/16
inch open
1/2 NPT
1/2 NPT
Page 5