- Wait five (5) minutes to allow possible
accumulated gas to clear.
- Set the IFT-ECM 3-position selector switch to ON
or REMOTE position. Module will beep once and
flash a three GREEN LED code on successful
startup.
- If placed in ON position, the appliance will ignite
normally if the error condition was corrected.
- If placed in REMOTE position, use the paired IFT-
RC400, IFT-RC150 or wired wall switch to start
the appliance; appliance will ignite normally if the
error condition was corrected.
- If the IFT-ECM re-enters the lock-out condition
after these steps, call your dealer for service.
Heat & Glo • 6000C-IFT, 8000C-IFT Owner's Manual • 2502-981 Rev. J • 12/20
IntelliFire Touch Ignition System
NOTICE: Batteries should only be used as a power source
in the event of an emergency power outage. Batteries
should not be used as a primary long-term power source.
Battery polarity must be correct when installing batteries.
When using batteries as a power source, the 6-volt
transformer must be unplugged from the receptacle.
Appliance ON/OFF:
A wall control, thermostat or remote control may be used
to control the ON/OFF function of the appliance. Follow
instructions included with the installed control.
Heat Management Systems
Optional Heat-Zone
-Gas Kit
®
The Heat-Zone
-Gas heat management option is available
®
for use with the 6000C-IFT and 8000C-IFT appliances.
The Heat-Zone
-Gas Kit draws heat from your fireplace
®
to an adjacent room in your home, up to 20 feet away.
Optional Heat-Out-Gas Kit
The Heat-Out-Gas heat management option is available
for use with the 6000C-IFT and 8000C-IFT appliances
and must be used in conjunction with the IFT-RC400
remote control. The Heat-Out-Gas kit draws heat from
your fireplace and directs it outside, up to 25 feet away.
Optional Heat-Duct Kit
The Heat-Duct heat management option is available for
use with the 6000C-IFT and 8000C-IFT appliances. The
Heat-Duct redistributes heat from the fireplace via the
furnace ductwork.
Optional Fan Kit
If desired, a fan kit may be added. Contact your dealer
to order the correct fan kit. Heat management for the fan
is discussed in Section 3.H. Detailed instructions are in-
cluded with the fan kit.