Planet ICS-2102ST User Manual

Planet ICS-2102ST User Manual

Uindustrial serial device server

Advertisement

Quick Links

User's Manual of ICS-2x00T Serial Device Server Series
RS232/RS422/RS485
Industrial Serial Device Server
ICS-2100T / ICS-2105AT/
ICS-2102T / ICS-2102ST/
ICS-2200T / ICS-2400T
1

Advertisement

Table of Contents
loading

Summary of Contents for Planet ICS-2102ST

  • Page 1 User’s Manual of ICS-2x00T Serial Device Server Series RS232/RS422/RS485 Industrial Serial Device Server ICS-2100T / ICS-2105AT/ ICS-2102T / ICS-2102ST/ ICS-2200T / ICS-2400T...
  • Page 2 PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners. Disclaimer PLANET Technology does not warrant that the hardware will work properly in all environments and applications, and makes no warranty and representation, either implied or expressed, with respect to the quality, performance, merchantability, or fitness for a particular purpose.
  • Page 3: Table Of Contents

    3.2 Web Management ............................27 3.2.1 Logging in to the Industrial Serial Server ......................27 3.3 Remote Management ........................... 29 3.4 PLANET Smart Discovery Utility ........................30 4. WEB CONFIGURATION ...................... 32 4.1 Main Web Page ............................35 4.2 System ................................36 4.2.1 System.................................
  • Page 4 User’s Manual of ICS-2x00T Serial Device Server Series 4.3 Accessible IP ..............................42 4.4 Network ................................ 43 4.5 Port Config..............................45 4.5.1 Serial setup ................................46 4.5.2 Operation mode ..............................47 4.5.2.1 Disable mode ............................47 4.5.2.2 Remote Pair Master/Slave mode ....................... 48 4.5.2.3 RF2217 mode ............................
  • Page 5: Introduction

    User’s Manual of ICS-2x00T Serial Device Server Series 1. INTRODUCTION Thank you for purchasing PLANET ICS-2100T Industrial Serial Device Server series. “Industrial Serial Server” is used as an alternative name in this Quick Installation Guide. ICS-2100T IP30 Industrial 1-Port RS232/RS422/RS485 Serial Device Server (1 x 10/100TX, -40~75 degrees C)
  • Page 6: Product Description

    Cost-effective Solution for RS232/422/485 Serial-to-Industrial Ethernet Application PLANET ICS-2x00T Serial Device Server series is specially designed to convert RS232, RS422 or RS485 serial communication to Industrial Fast Ethernet networking so as to extend the network distance efficiently and inexpensively. There are one/two 10/100BASE-TX RJ45 ports available in the ICS-2x00T series for your network needs.
  • Page 7 User’s Manual of ICS-2x00T Serial Device Server Series Remote Management As the ICS-2x00T series provides an easy serial-to-Ethernet connectivity and connection to a TCP/IP network, the remote network system can thus be managed efficiently via its Web, Telnet and VCOM management interfaces. It supports both application and serial operation modes for alarm or IP address connection, which saves the network administrator’s time in detecting and locating network problems without visual inspection of the cabling and devices.
  • Page 8 User’s Manual of ICS-2x00T Serial Device Server Series Dual Power Input for High Availability Network System The ICS-2x00T series features a strong dual power input system with wide-ranging voltages (12V~48V DC or 9 to 48V DC / 24V AC) incorporated into customer’s automation network to enhance system reliability and uptime. In the example below, when Power Supply 1 fails to work, the hardware failover function will be activated automatically to keep powering the ICS-2x00T series via Power Supply 2 without any break of operation.
  • Page 9 User’s Manual of ICS-2x00T Serial Device Server Series Effective Alarm Alert for Better Protection The ICS-2x00T series comes with a Fault Alarm feature which can alert the users when there is something wrong with the Serial Device Server. With this ideal feature, the users would not have to waste time finding where the problem is. It will help to save time and human resource.
  • Page 10: How To Use This Manual

    User’s Manual of ICS-2x00T Serial Device Server Series 1.3 How to Use This Manual This User’s Manual is structured as follows: Section 2, INSTALLATION It explains the functions of the ICS-2X00T and how to physically install the ICS-2X00T. Section 3, INDUSTRIAL SERIAL SERVER MANAGEMENT The chapter explains how to manage the ICS-2X00T in different ways.
  • Page 11: Product Features

    Built-in buzzer Relay output alarm Digital output (ICS-2400T only)  DHCP client for IP address assignment  PLANET Smart Discovery utility automatically finds the client devices on the network  Industrial Case and Installation  IP30 metal case  IP40 metal case (ICS-2400T only) ...
  • Page 12 User’s Manual of ICS-2x00T Serial Device Server Series − 12 to 48V DC, redundant power with reverse polarity protection (ICS-2200T/2400T)  Supports 6000 VDC Ethernet ESD protection  -40 to 75 degrees C operating temperature  Free fall, shock-proof and vibration-proof for industries ...
  • Page 13: Product Specifications

    User’s Manual of ICS-2x00T Serial Device Server Series 1.5 Product Specifications ICS-2102T Product ICS-2100T ICS-2105AT ICS-2200T ICS-2400T ICS-2102ST Serial Interface 1 x DB9 male for RS232 Serial Ports 2 x DB9 male 4 x DB9 male 1 x 4-pin Terminal block for RS422 / RS485 Serial Standards...
  • Page 14 < 5 sec: System reboot Reset Button > 5 sec: Factory default Management Web management Telnet Console management Management Interfaces Windows-based VCOM Utility management PLANET Smart Discovery Utility IP Version IPv4 and IPv6 TCP Server TCP Client Operation Mode UDP Client Virtual COM...
  • Page 15 User’s Manual of ICS-2x00T Serial Device Server Series Telnet Server Pair Connection – Remote (Slave) Pair Connection – Local (Master) Modbus converter server / client Windows-based only: Windows XP Windows Server 2003 Virtual COM Utility Windows 7 Platform Supports Windows Server 2008 Windows 8 (Must install the latest version of WinPcap) Windows Server 2012 (Must install the latest version of WinPcap) Windows 10...
  • Page 16: Installation

    User’s Manual of ICS-2x00T Serial Device Server Series 2. INSTALLATION This section describes the hardware features and installation of the Industrial Serial Servers' components on the desktop or rack. For easier management and control of the Industrial Serial Servers, familiarize yourself with its display indicators, and ports. Front panel illustrations in this chapter display the LED indicators.
  • Page 17 User’s Manual of ICS-2x00T Serial Device Server Series ICS-2200T ICS-2400T Figure 2-1-1: Front Panels of Industrial Serial Servers ■ Fast TP/ SFP interface 10/100BASE-TX copper, RJ45 twisted-pair: Up to 100 meters. 100BASE-FX SFP interface, Up to 2km~120km, vary on SFP modules. ■...
  • Page 18: Front Panel

    User’s Manual of ICS-2x00T Serial Device Server Series 2.1.2 Front Panel The Reset Buttons of the Industrial Serial Servers are shown in Figure 2-1-2. ICS-2100T ICS-2105AT ICS-2200T ICS-2400T Figure 2-1-2: Reset Button of Industrial Serial Servers ■ Reset button On the bottom panel, the reset button is designed for rebooting the system and stopping the buzzer. The following is the summary table of the reset button functions: Reset Button Pressed and...
  • Page 19: Led Indications

    User’s Manual of ICS-2x00T Serial Device Server Series 2.1.3 LED Indications The front panel LEDs indicate instant status of power and system status, fan status, port links and data activity; they help monitor and troubleshoot when needed. LED indication ■ System Color Function Lights...
  • Page 20: Wiring The Power Inputs

    Insert positive/negative DC power wires into Contacts 1 and 2 for Power 1, or Contacts 5 and 6 for Power 2. Figure 2-1-3 to 2-1-5 show PWR1 and PWR2 of the Industrial Serial Server.  ICS-2100T/ICS-2105AT/ICS-2102T/ICS-2102ST: 9~48V DC or 24V AC Figure 2-1-3 ICS-2100T/ICS-2105AT Upper Panel ...
  • Page 21: Serial Port Pin Define

    User’s Manual of ICS-2x00T Serial Device Server Series Power 1 Fault Power 2 Figure 3-3 PWR1 & PWR2 pina of terminal block. The wire gauge for the terminal block should be in the range from 12 to 24 AWG. 2.1.5 Serial Port Pin Define...
  • Page 22: Installing The Industrial Serial Server

    User’s Manual of ICS-2x00T Serial Device Server Series 2.2 Installing the Industrial Serial Server This section describes how to install your Industrial Serial Server and make connections to the Industrial Serial Server. Please read the following section and perform the procedure in the order being presented. To install your Industrial Serial Server on a desktop or rack, simply complete the following steps.
  • Page 23: Din-Rail Mounting

    User’s Manual of ICS-2x00T Serial Device Server Series 2.2.2 DIN-rail Mounting This section describes how to install the Industrial Serial Server. There are two methods to install the Industrial Serial Server -- DIN-rail mounting and wall-mount plate mounting. Please read the following section and perform the procedure in the order being presented.
  • Page 24 User’s Manual of ICS-2x00T Serial Device Server Series Step 3: Check whether the DIN-rail bracket is tightly on the track. Please refer to the following procedure to remove the Industrial Serial Server from the track. Step 4: Lightly remove the unit from the track.
  • Page 25: Wall Mount Plate Mounting

    User’s Manual of ICS-2x00T Serial Device Server Series 2.2.3 Wall Mount Plate Mounting To install the Industrial Serial Server on the wall, please follow the instructions below. Follow all the DIN-rail installation steps as shown in the example. Step 1: Remove the DIN-rail bracket from the Industrial Serial Server. Use the screwdriver to loosen the screws to remove the DIN-rail.bracket.
  • Page 26: Industrial Serial Server Management

    Requirements  Web Management  Remote Management  PLANET Smart Discovery Utility 3.1 Requirements  Workstations running Windows 2000/XP, 2003, Vista/7/8/10, 2008, MAC OS9 or later, or Linux, UNIX , or other platforms compatible with TCP/IP protocols.  Workstation is installed with Ethernet NIC (Network Interface Card) ...
  • Page 27: Web Management

    User’s Manual of ICS-2x00T Serial Device Server Series 3.2 Web Management The Industrial Serial Server offers management features that allow users to manage the Industrial Serial Server from anywhere on the network through a standard browser such as Microsoft Internet Explorer. After you set up your IP address for the switch, you can access the Industrial Serial Server's Web interface applications directly in your Web browser by entering the IP address of the Industrial Serial Server.
  • Page 28 User’s Manual of ICS-2x00T Serial Device Server Series After entering the password, the main screen appears as shown in Figure 3-2-3. Figure 3-2-3: Web Main Screen of Industrial Serial Server The Main Menu in the middle of the Web page lets you access all the functions and statuses. It appears as shown in Figure 3-2-4.
  • Page 29: Remote Management

    User’s Manual of ICS-2x00T Serial Device Server Series 3.3 Remote Management The Industrial Serial Server also supports Telnet for remote management. You can use Telnet to open a terminal session over one of the Ethernet ports. The Serial Server asks for user name and password for remote login when using Telnet; please use the following default IP address, username and password for the first-time login.
  • Page 30: Planet Smart Discovery Utility

    3.4 PLANET Smart Discovery Utility For easily listing the Industrial Serial Server in your Ethernet environment, the Planet Smart Discovery Utility is an ideal solution. The following installation instructions are to guide you to running the Planet Smart Discovery Utility.
  • Page 31 To click the “Control Packet Force Broadcast” function, it allows you to assign a new setting value to the Web Smart Switch under a different IP subnet address. Press the “Connect to Device” button and the Web login screen appears as shown in Figure 3-4-2. Press the “Exit” button to shut down the Planet Smart Discovery Utility.
  • Page 32: Web Configuration

    User’s Manual of ICS-2x00T Serial Device Server Series 4. WEB CONFIGURATION This section introduces the configuration and functions of the Web-based management from Industrial Serial Server. About Web-based Management The Industrial Serial Server offers management features that allow users to manage the Industrial Serial Server from anywhere on the network through a standard browser such as Microsoft Internet Explorer.
  • Page 33 User’s Manual of ICS-2x00T Serial Device Server Series  Logging on to the Industrial Serial Server Use Internet Explorer 7.0 or above Web browser. Enter the factory default IP address to access the Web interface. The factory default IP address is shown as follows: Default IP Address: 192.168.0.100 Default Username: admin Default Password: admin...
  • Page 34 User’s Manual of ICS-2x00T Serial Device Server Series Now, you can use the Web management interface to continue the switch management or manage the Industrial Serial Server by Web interface.
  • Page 35: Main Web Page

    User’s Manual of ICS-2x00T Serial Device Server Series 4.1 Main Web Page The Industrial Serial Server provides a Web-based browser interface for configuring and managing it. This interface allows you to access the Industrial Serial Server using the Web browser of your choice. The main web page is shown in Figure 4-1-4 Figure 4-1-4: Web Main Page Main Menu...
  • Page 36: System

    User’s Manual of ICS-2x00T Serial Device Server Series 4.2 System Use the System menu items to display and configure basic administrative details of the Industrial Serial Server. Under the System, the following topics are provided to configure and view the system information. This section has the following items: ■...
  • Page 37 User’s Manual of ICS-2x00T Serial Device Server Series IPv4 Configuration Object Description • IP Configuration The status of IPv4 configuration. • IP Address The current IPv4 address of the device. • Subnet Mask The current IPv4 subnet mask of the device. •...
  • Page 38: Port

    User’s Manual of ICS-2x00T Serial Device Server Series 4.2.2 Port This Port page displays the status of each port, including operation mode and serial settings. The screen in Figure 4-2-2 appears. Figure 4-2-2: Port Status Page Screenshot The following column shows the Port statuses: Object Description •...
  • Page 39: Device

    User’s Manual of ICS-2x00T Serial Device Server Series 4.2.3 Device This page provides configuration of device name and syslog server. The screen in Figure 4-2-3 appears. Figure 4-2-3: Device Setup Page Screenshot The page includes the following fields: Object Description •...
  • Page 40: Console

    User’s Manual of ICS-2x00T Serial Device Server Series 4.2.5 Console This page is to configure management methods for web and remote console. The screen in Figure 4-2-5 appears. Figure 4-2-5: Console Setup Page Screenshot The page includes the following fields: Object Description •...
  • Page 41: Digital Input And Output

    User’s Manual of ICS-2x00T Serial Device Server Series 4.2.7 Digital Input and Output Digital Input allows user to log external device (such as industrial cooler). System will log a user customized message into system log and issue SNMP trap. Digital Output allows user to monitor whether the power or DCD/DSR signal has changed, and let system issue a high or low signal to an external device (such as alarm) when power fails.
  • Page 42: Accessible Ip

    User’s Manual of ICS-2x00T Serial Device Server Series 4.3 Accessible IP This page provides the specified IP address to connect with industrial serial server. When the list of accessible IP is enabled, only IP address in the list can connect to device. When the function is disabled, there is no such restriction. List allows user to configure up to four IP groups.
  • Page 43: Network

    User’s Manual of ICS-2x00T Serial Device Server Series 4.4 Network This page allows the user to configure IPv4 or IPv6 address. The IP configuration screen in Figure 4-4-1 appears. Figure 4-4-1: IP Configuration Page Screenshot The page includes the following fields: IPv4 Object Description...
  • Page 44 User’s Manual of ICS-2x00T Serial Device Server Series • Prefix The IPv6 network mask, in number of bits (prefix length). The default value is 64. • Gateway The default gateway for the IPv6 interface. • Primary DNS Configure the first DNS server. •...
  • Page 45: Port Config

    User’s Manual of ICS-2x00T Serial Device Server Series 4.5 Port Config The following figure shows port settings. Note that these settings need to match the parameters on serial port of the serial device. Each parameter is described in details in the following section. The port configuration screen in Figure 4-5-1 appears.
  • Page 46: Serial Setup

    User’s Manual of ICS-2x00T Serial Device Server Series 4.5.1 Serial setup The serial setup screen is shown in Figure 4-5-2. Figure 4-5-2: Serial Setup Page Screenshot Object Description • Description Used to distinguish the name of each serial port. It allows 1 to 15 characters (e.g. A-Z, a-z, 0-9) •...
  • Page 47: Operation Mode

    User’s Manual of ICS-2x00T Serial Device Server Series 4.5.2 Operation mode The industrial serial server makes connected Serial equipment become IP-based. That also makes them able to connect to a TCP/IP networking immediately. The industrial serial server allows traditional Computer/Client COM ports access to a serial equipment anywhere on the Ethernet LAN network.
  • Page 48: Remote Pair Master/Slave Mode

    User’s Manual of ICS-2x00T Serial Device Server Series 4.5.2.2 Remote Pair Master/Slave mode When a device connected to an industrial serial server can be transparently connected to another device on industrial serial server; data and modem control signals are exchanged. This protocol can overcome the limitations of traditional serial communication distances and introduce many new usability and feasibility for serial device control.
  • Page 49 User’s Manual of ICS-2x00T Serial Device Server Series The remote pair slave mode screenshot in Figure 4-5-7 appears. Figure 4-5-7: Remote Pair Slave Mode Screenshot The page includes the following fields: Object Description • TCP Keep-alive TCP keep alive interval shows how many seconds the unit waits during an inactive Interval connection before checking its status.
  • Page 50: Rf2217 Mode

    User’s Manual of ICS-2x00T Serial Device Server Series 4.5.2.3 RF2217 mode RS232 to Ethernet Connector allows to choose the transmission protocol, supporting connections using either the RAW data transmission algorithm or the Telnet (RFC 2217) protocol.Therefore, Telnet can act as an interface to a network device server connected to a remote serial device.
  • Page 51: Serial Telnet Mode

    User’s Manual of ICS-2x00T Serial Device Server Series 4.5.2.4 Serial Telnet mode Telnet (TELecommunication NETwork) is a network protocol used on the Internet or local area network (LAN) connections. The Telnet protocol type is the correct setting for most servers and serial devices, such as Managed Ethernet switches or Gateways. In the case of a Telnet session, the process is reversed, where the connected server reads and writes data to RS-232 serial port.
  • Page 52 User’s Manual of ICS-2x00T Serial Device Server Series Example: Use Putty TCP/IP Winsock mode PuTTY is a free implementation of Telnet and SSH for Win32 and Unix platforms, along with an xterm terminal emulator. In this case we use PuTTY to connect GS-5220-24P4XV managed switch via ICS-2400T. Figure 4-5-11: Serial Telnet Mode Application ICS-2400T Set Port Configuration as shown below.
  • Page 53 User’s Manual of ICS-2x00T Serial Device Server Series Then it can connect to switch successfully. Figure 4-5-14: Putty Connection...
  • Page 54: Tcp Server Mode

    User’s Manual of ICS-2x00T Serial Device Server Series 4.5.2.5 TCP Server mode When the serial server is configured as a TCP server, it waits for a connection initiated by another network device. User must set the local TCP port number for which it will listen for the connection, and the industrial serial server provides the maximum number of two concurrent connections.
  • Page 55 User’s Manual of ICS-2x00T Serial Device Server Series the network. This parameter is 0 to indicate that the data will not be packed until the buffer is full. The range of value is from 0 to 1024. The default is 0. •...
  • Page 56 User’s Manual of ICS-2x00T Serial Device Server Series Set operation mode as Telnet Server mode. Figure 4-5-19: TCP Server Mode Configuration Run the modbus master application (e.g. Modbus Poll) and set parameters as shown below. Figure 4-5-20: Modbus application Configuration Modbus master application (e.g.
  • Page 57: Tcp Client Mode

    User’s Manual of ICS-2x00T Serial Device Server Series 4.5.2.6 TCP Client mode The TCP client initiates a connection to the server on the network. You must set up the target IP address and assigned local port number of server that you want the client to communicate with. In the data transmission phase, the data is transmitted to the destination in the order to which they are sent.
  • Page 58 User’s Manual of ICS-2x00T Serial Device Server Series achieve communication. The range of value is from 1 to 65535. The default is 5004 for port 1, 5005 for port 2, 5006 for port 3 and , 5007 for port 4. •...
  • Page 59: Udp Mode

    User’s Manual of ICS-2x00T Serial Device Server Series 4.5.2.7 UDP mode UDP is a Connectionless of the non-reliable transmission protocol; it does not need to verify information and does not guarantee correctness for some of the larger amount of information. The reliability is greater than the reliability of transmission which is a good choice.
  • Page 60 User’s Manual of ICS-2x00T Serial Device Server Series buffered characters, including the start and end separators, are sent to the network. The range of value is from 0 to FF. The default is disable. • Separator Process Separators are ASCII characters specified by the user when configuring the serial serve. This parameter describes how to control characters received on a serial port are sent across the network.
  • Page 61: Virtual Com Mode

    User’s Manual of ICS-2x00T Serial Device Server Series 4.5.2.8 Virtual COM mode VCOM mode functionality provides a virtual-local COM port for Windows systems. The VCOM driver should be installed on the PC through the VCOM Administration Utility. The driver establishes a TCP connection to the connected serial device by mapping the local serial port to the IP port of the device port.
  • Page 62 User’s Manual of ICS-2x00T Serial Device Server Series  Do nothing: it will pack the accumulated data including Separators.  Strip Separator: it controls striping of Separator from the received characters before the received characters are sent to the network. •...
  • Page 63 User’s Manual of ICS-2x00T Serial Device Server Series Run VCOM software to set port mapping. Port 1 is related to COM4 port. Figure 4-5-31: VCOM Software Run the modbus master application (e.g. Modbus Poll) and set parameters as shown below. Figure 4-5-32: Modbus application Configuration Modbus master application (e.g.
  • Page 64: Modbus Converter Server Mode

    User’s Manual of ICS-2x00T Serial Device Server Series 4.5.2.9 Modbus Converter Server mode The ICS Serial devices support standard Modbus protocol and various hardware interfaces (serial and Ethernet). Modbus TCP and RTU can be used to convert the Modbus protocol. The Modbus master can communicate with the serial network of devices connected to the serial port of the server converter via a server converter.
  • Page 65 User’s Manual of ICS-2x00T Serial Device Server Series achieve communication.
  • Page 66: Modbus Converter Client Mode

    User’s Manual of ICS-2x00T Serial Device Server Series 4.5.2.10 Modbus Converter Client mode The ICS Serial devices support standard Modbus protocol and various hardware interfaces (serial and Ethernet). Modbus TCP and RTU can be used to convert the Modbus protocol. The Modbus master can communicate with the serial network of devices connected to the serial port of the server converter via a server converter.
  • Page 67 User’s Manual of ICS-2x00T Serial Device Server Series Connection Target IP address Object Description • Target IP address 1 IP addresses are used to deliver packets of data across a network and have what is through 4 termed end-to-end significance. The network data is sent to the device in a first-in, first-out (FIFO) method.
  • Page 68: Snmp Setup

    User’s Manual of ICS-2x00T Serial Device Server Series 4.6 SNMP Setup Use the Port Menu to display or configure the Industrial Industrial Serial Server's ports. This section includes the page that displays current port configurations. Ports can also be configured here. The Port Configuration screen in Figure 4-6-1 appears.
  • Page 69: Maintenance

    User’s Manual of ICS-2x00T Serial Device Server Series 4.7 Maintenance Use the Port Menu to display or configure the Industrial Industrial Serial Server's ports. This section includes the page that displays current port configurations. Ports can also be configured here. 4.7.1 Change Password After logging in to the industrial serial server, user can make changes from the "Change Password"...
  • Page 70: Firmware Update

    User’s Manual of ICS-2x00T Serial Device Server Series 4.7.3 Firmware Update This page facilitates an update of the firmware controlling the switch. The Firmware Update screen in Figure 4-7-3 appears. Figure 4-7-3: Firmware Update Page Screenshot To open Firmware Update screen, perform the following: Click Maintenance ->...
  • Page 71: Save And Restart

    User’s Manual of ICS-2x00T Serial Device Server Series 4.8 Save and Restart When applying any configuration changes of industrial serial server, it’s required to save changed configuration and reboot system. Therefore the new configuration will be applied after rebooting. The Save and Restart screen in Figure 4-8-1 appears.
  • Page 72: Software Vcom Utility

    User’s Manual of ICS-2x00T Serial Device Server Series 5. SOFTWARE VCOM UTILITY The industrial serial server provides VCOM software to manage serial devices. With VCOM software, it’s easy to install and configure industrial serial server over the network. It also supports central management to manage multiple serial servers from one site.
  • Page 73 User’s Manual of ICS-2x00T Serial Device Server Series 3. The setup wizard will show the progress of the installation and status as shown in Figure 5-1-3. Figure 5-1-3 : Installing Process 4. Click Finish to successfully complete installation of VCOM software.as shown in Figure 5-1-4.
  • Page 74: Search Devices

    User’s Manual of ICS-2x00T Serial Device Server Series 5.2 Search Devices First click "Add Device" and then click "Search", if device has access to network, as shown in Figure 5-2-1. Figure 5-2-1 : Searching Devices After adding an ICS-2400T device as shown in Figure Figure 5-2-2.
  • Page 75: Virtual Com

    User’s Manual of ICS-2x00T Serial Device Server Series 5.3 Virtual COM This function should be set as VCOM mode on the industrial serial server. VCOM software will create the corresponding virtual COM ports for com port mapping as shown in Figure 5-3-1.
  • Page 76 User’s Manual of ICS-2x00T Serial Device Server Series From the Windows Device Manager, four COM Ports are added to the device list as shown in Figure 5-3-4. Figure 5-3-4 : Virtual COM Ports...

This manual is also suitable for:

Ics-2105atIcs-2102tIcs-2100tIcs-2200tIcs-2400t

Table of Contents