Docking Station PCA, Docking Mechanism Assembly, and
Control PCA
(HP Authorized Support Providers Only)
Docking Station PCA:
1. Disconnect the Control Harness from the Docking Station PCA (see Figure 4).
2. Remove the two 6-32 L=0.188 screws from front corners of the Docking Station PCA (screws
not shown in Figure 4).
3. Disconnect the cable connecting the Docking Mechanism Assy to the Docking System PCA.
4. Turn the Docking Station PCA over and remove the four screws from the bottom. This will
free the Docking Mechanism Assembly.
5. The Control PCA simply lifts out at this point. Refer to Figure 5 for proper placement of
the Control Harness. Improper placement will crimp the harness and may result in
loss of control button functionality.
6. Reverse the above steps to reassemble.
Screw 6-32
L=0.188
(Qty 4)
Editor's Note: A
small washer is
located on this
raised standoff/
screwhole.
Control Harness
Control PCA
Figure 4 - Docking Station PCA, Docking Mechanism Assembly, and Control PCA
Docking Mechanism
Assy
__________
10
Docking System
PCA
Rod Switch
Plunger
Plunger Spring
Base Assy