9-2-10 Compressor starting error

Indoor display
7-SEG DISPLAY
C461
Outdoor display
LED ON
LED BLINKING
1. Checklist :
1) Is the connection of cable for the compressor?
2) Is the compressor wire is connected clockwise? U(RED)-V(BLU)-W(YEL)
3) Is the interphase resistance of compressor normal?
2. Troubleshooting procedure
Restart after power off.
Is the restart error occurred again?
YES
Is the connection of compressor wire is normal?
YES
Download the EEPROM data
Is the restart error occurred again?
YES
Is the compressor body and interphase
resistance insulated?
YES
Exchange the compressor
DESCRIPTION
Comp starting error
LED OFF
NO
NO
NO
NO
58
Comp starting error
Terminate the service
Connect the comp wire normally
Terminate the service
Exchange the Outdoor PBA