Siemens SIMATIC NET SCALANCE W M766-1 Series Reference Manual page 45

Industrial wireless lan approvals scalance w700 802.11ax
Hide thumbs Also See for SIMATIC NET SCALANCE W M766-1 Series:
Table of Contents

Advertisement

Country
Russian Federation
1) In this country the use of 80 MHz channel width is not permitted in the channels 52 to 140.
2) Maximum permissible gain: Antenna and additional attenuation elements
Maximum permissible gain: Antenna and additional attenuation elements
When using antennas with a very high antenna gain, the maximum permitted EIRP
(equivalent isotropic radiated power) of the device is often exceeded even at minimum
transmit power. Additional attenuation elements must therefore be used between the
device and the antennas. The "Max. permitted gain" column in the table above shows the
maximum permitted antenna gain (total value) that can be connected to the antenna
sockets of the devices. If the typical antenna gain of the antennas to be connected
exceeds the maximum permissible value, you must compensate for the difference by
using attenuation elements, for example, an attenuator or connecting cables.
The following table provides an overview of possible attenuation elements and their
attenuation values:
Name
Attenuator
Antenna connecting cable, 1 m long
Antenna connecting cable, 2 m long
Antenna connecting cable, 5 m long
Example
The antenna ANT793-8DL is used.
• Typical antenna gain: 14 dBi
• Maximum permissible gain for channel 36 in Germany: 11 dBi
In this case the typical antenna gain exceeds the maximum permissible gain by 3 dBi.
This means you must use an attenuation element with at least 3 dB. This can be a
connecting cable, for example, with a length of 5 meters.
Approvals SCALANCE W700 802.11ax
Reference Manual, 03/2022, C79000-G8976-C621-03
Mode
CH
11g 11n
1
-
13
11a 11ac 11ax
36
11n
-
64
132
-
144
11a 11ac 11ax
149
11n
-
165
MHz
PWR
Max. permitted
(EIRP)
2412
100 mW
-
2472
5180
200 mW
-
5320
5660
200 mW
-
5720
5745
200 mW
-
5825
Attenuation
10 dB
1.0 dB
1.8 dB
4.3 dB
SCALANCE WxM763-1
2.6 National approvals
Use
gain
-
Indoor + Outdoor
-
Indoor only
-
Indoor only
-
Indoor only
Article number
6GK5798-0AP00-4CA0
6XV1875-5xH10
6XV1875-5xH20
6XV1875-5xH50