SPECIFICATIONS

MODEL
FAN MOTOR
FAN MOTOR CAPACITOR
FAN MOTOR PROTECTOR
COMPRESSOR
COMPRESSOR MOTOR CAPACITOR
OVERLOAD PROTECTOR
OVERHEAT PROTECTOR
FUSE (for MICROPROCESSOR)
POWER RELAY
POWER SWITCH
TEMPORARY SWITCH
TEST/SERVICE SWITCH
TRANSFORMER
VARISTOR
NOISE SUPPRESSOR
THERMOSTAT
REMOTE CONTROL SWITCH (LIQUID CRYSTAL)
REFRIGERANT CHARGING
VOLUME
(Refrigerant R410A)
UNIT
PIPES (MAX. 30m)
PIPES
(MIN.
3m)
– 5 –
RAS-60YH7
30 W
NO
NO
NO
NO
NO
3.15A
G4A
NO
YES
NO
NO
416NR
NO
YES(IC)
YES
-----------
CHARGELESS
RAC-60YH7A
47 W
NO
NO
JU1015D9
NO
YES (INTERNAL)
YES
3.15A
G4A
NO
NO
YES
NO
450NR
YES
YES(IC)
NO
❈ 1650g