12. UPPER CLOTH CLAMP HEIGHT AND PRESSURE

CAUTION : Switch off the main switch before adjustment.
A) Upper cloth clamp height
a) Raise the cloth feed table and fix it. Loosen the screw ①.
b) Loosen the nut ②, rotate the screw ③ until the upper cloth clamp height comes 10mm.
c) Tighten the nut ② and the screw ①.
B) Upper cloth clamp pressure
a) Loosen the nut (A) and the screw (B). Loosen the nut (C), move the shaft (D) up or down until the shaft
(D) comes to nearly the center of groove for flat type cloth clamp. In case of wedge type cloth clamp, the
shaft (D) is about 2mm under from the center of groove.
b) After adjusting, tighten the nut (C). Tighten the screw (B) until it hits to the shaft (D) and tighten the nut
(A).
CUTION: If the pressure is to high, the motor stops caused by high pressure.
                                                                           
A)Upper cloth clamp height

13. SPREADING CLOTH CLAMP PLATE

CAUTION : Switch off the main switch before adjustment.
Parallel of cloth clamp plate:
The distance in the point of (A) and (A') should be the same amount when the machine is the start position.
If the distance is incorrect, adjust it as follows.
a) Loosen the screw ①, push the cloth clamp against the edge of feed table and keep the position.
b) Tighten screw ①.
Spreading cloth clamp plate:
The standard distance (B) of left and
right cloth clamp plate is about 2mm
when the cloth clamp is original
position/unlocked. The distance will
be depend on material/fabric or C/A,
C/B sewing.
Loosen the screw ②,
adjust the cloth clamp plate to desired
position.
NOTE: Wide distance – The cloth
clamp plate spreads widely.
Narrow distance – The cloth clamp
plate spreads narrowly.
9
B)Upper cloth clamp pressure
Nearly center
of groove for the
flat type clamp.