EXTRACTOR HOOD

EN
Dear Customer,
Thank you for buying our hood. Please read these instructions carefully
for its optimum installation, use and maintenance.
Notes: The figures mentioned in this manual are in the first pages.
This hood is designed for fitting in a cabinet or on some other support.
Warning: consult local regulations regarding fumes outlets. Do not
connect the hood to a fume, ventilation or hot air duct. Confirm
that room ventilation is appropriate with the local authorities.
Make sure
the maximum air extraction flow rate for the appliances in the room
does not exceed 4 Pa (0.04 mbar).The room must have adequate
ventilation if an extractor hood is used simultaneously with appliances
that run on gas or other fuels. The evacuated air must be extracted
through ducts that are used for evacuating fumes from appliances that
run on gas or other fuels. Regulations regarding air extraction must be
complied with.
This product in intended for HOUSEHOLD USE only.
Use a rigid PVC pipe with a min. Ø l20 mm to evacuate fumes outside.
The above restrictions do not apply to hoods with no fumes outlet to outside
(recirculation system with activated charcoal filter).
Install the hood in line with the instructions on the template.
For gas cooking appliances only: the minimum distance to the hood
must be at least 65 cm.
Warning: Failure to install the screws or fixing device in accordance
with these instructions may result in electrical hazards.
INSTALLATION
The cooker hood is supplied with
3 Spacer (F, H)
4 Screws (C)
2 Bulbs
To fixing the Hood, use the 4 screws (C) Ø6mm supplied with the hood.
Close the space that remains between the hood and the wall,
adjunsting the spacer (F).
Before completing any connection, make sure the house voltage
corresponds with the voltage indicate on the data label.
Connecting the hood to the grid
Warning: before connecting the hood: switch off the electricity
supply and check that the supplied voltage and frequency
coincide with that indicated on the appliance nameplate.
If the extractor hood has a plug, connect it to a power socket in line
with applicable regulations, located in an accessible area.
If the hood does not have a plug, connect it directly to the electrical
grid, protected by a separator device accessible for disconnection, in
line with local regulations.
The connection to the electrical mains must be made as follows:
BLUE............................."N" NEUTRAL
BROWN.........................."L" LIVE
GREEN AND YELLOW......(simbolo tierra) EARTH
If the terminals of the plug are unmarked or if you are in any doubt
consult a qualified electrician.
If it is not supplied fit a plug normalized in the cord for the load showed
on the rating plate.
USE OF THE HOOD – SAFETY
Warning: the hood may stop working during an electrostatic
discharge (e. g. lightning). This involves no risk of damage. Switch
off the electricity supply to the hood and reconnect after one
minute.
This appliance can be used by children aged from 8 years and above
and persons with reduced physical, sensory or mental capabilities or
lack of experience and knowledge if they have been given supervision
or instruction concerning use of the appliance in a safe way and
understand the hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall not be made by
children without supervision.
To avoid the risk of fire, clean the metal filter regularly, permanently control
pans containing hot oil and do not flambé food underneath the hood.
Do not use the hood if it shows signs of damage or imperfection.
Contact an official distributor or authorised dealer.
Accessible parts may heat up when using cooking appliances.
Air Intake Speed (Fig 2)
The front panel has to be pulled its maximum extension so as to optimise
the extraction capacity.
The three setting switch (C-2) has the following functions:
0 Stop
1 Low Speed
2 High Speed
Switch on the Lamps (C-1 Fig 2)
Pull out the grill (G) more than 50mm
SUCTION VERSION
If the hood is to be installed as a SUCTION hood, connect the plastic
outlet piece (A) supplied with the hood (120mm diameter pipe for
better performance and lower noise levels.
FILTERING VERSION (INTERNAL RE-CYCLING)
When there is no exhaust duct for venting out-door, you can use a
carbon filter (D). The air is depurate by the filter and put again in the
surrounding.
The air is released in the room through a connecting pipe, which goes
through the hanging cupboard and us connected to the connecting
ring supplied (A) Fig 1.
To use the appliance in this version, proceed as follows:
Open the grids (E)
To proceed to change the charcoal filter (D), the screw (B)
has to be removed.
Reinstall the grids.
HOOD MAINTENANCE
Warning: always switch off the electricity supply before carrying
out maintenance work on the hood. In the event of a fault,
contact an official distributor or authorised dealer.
Exterior cleaning: use non-corrosive, liquid detergent and avoid the use
of abrasive cleaning products.
Grease filters: to avoid fires, clean thoroughly once a month. To do so,
remove the filters and wash with hot water and detergent. If using a
dishwasher, position the filters vertically to prevent solid remains from
depositing on them.
Activated charcoal filters: replace the every 2 months.
Important: increase the filter cleaning/replacement frequency if the
hood is used for more than 2 hours a day. Always use genuine filters
from the manufacturer.
Bulb replacement (look for the
Warning: do not handle the bulbs until the electricity supply has been
switched off and they have cooled.
Important: use new bulbs according to that indicated on the
hood nameplate.
Use bulbs with an aluminium reflector to replace halogen bulbs. Do
not use dichroic bulbs - risk of overheating.
On cooker hoods equipped with tungsten lamps, the lights should
only be used during operation of the motor. They should not be left on
permanently and used as a light source.
Legal information
The manufacturer:
- Declares that this product meets all basic requirements regarding low-
voltage electrical equipment established in Directive 2006/95/EC of
12 December 2006 and electro-magnetic compatibility established in
Directive 2004/108/EC of 15 December 2004.
- Is not responsible for any failure to observe the instructions given in
this manual and current safety regulations for the correct use of the
equipment.
- Reserves the right to make any modifications to the equipment or this
manual without prior notice.
Contact our official distributor should you require technical assistance
or additional information on our products.