Installing The Hood - ILVE CH900X Instruction Manual

Ceiling hood
Table of Contents

Advertisement

INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS FOR
RANGE HOODS DESIGNED FOR WALL FITTING 230 Vac • 50 Hz
Exhausting cooker hood
The equipment is constructed in accordance with
European Standards and the requirements included in
the following Directives: 73/23 EEC (electric-low tension
safety), 89/336 EEC (electromagnetic compatibility),
93/68 EEC (EC marking regulations).
Before installing and/or using the hood:
• read all the instructions thoroughly;
• be sure that the ceiling structure is suitable for the
installation of this heavy equipment
• make sure that the voltage (V) and frequency (Hz)
ratings indicated on the plate inside the hood unit
correspond to the ones available in the installation
place.
• At least two people are needed for the installation
procedure, which it is advisable to entrust to competent
technicians.
USE
This cooker hood can be employed as exhausting
or filtering. Exhausting (external evacuation). Kitchen
smokes are driven outside through a flue (not provided
with the hood) joined to the exhaust pipe flue connector.
This pipe must not under any circumstances be
connected to cooker, boiler or burner exhaust pipes,
etc.
The use of pipes and holes on the wall with a smaller
diameter than the output of the motor will cause a
decrease in suction performance and an increased of
the noise level.
Use as short as possible tubes and with few curves.
Use pipes with smooth internal surfaces.
Filtering (inside recycling). The fumes pass through
activated carbon filters (supplied with the hood) to be
purified and recycled into the kitchen.
1. INSTALLATION
Read the instruction manual before installing and/or
using the hood. The minimum distance between the
supporting surface of the cooking hob and the lowest
part of the range hood must be not less than 65cm with
a gas hob. If the mounting instructions of the gas hob
indicate a wider distance, respect it.
The unit must not be mounted above cookers fitted
with top radiant plate.
For proper operation, it is recommended to install the
product at a distance of 200 – 210 cm from the floor.
Respect all the air discharge regulations.
The air must not be discharged in a pipe used to
discharge exhaust fumes produced by gas-fed
equipment or fuel-fed equipment (this does not apply to
filtering hoods).
The room must be adequately ventilated when
the hoods is used together with other gas or fuel
equipment.
For an easy access, it is advisable to move possible
furniture under the installation area.

INSTALLING THE HOOD

The hood can be installed in 2 different ways:
• Fixed directly to the ceiling:
This method of fixing can only be achieved if the distance
between the ceiling and the false ceiling is between 260
and 318mm.
For fixing, use the appropriate adjustable brackets
(Fig. 5).
Perform the following steps in order:
1. Make an opening in the false ceiling following the
dimensions shown in Fig. 1. 2. Drill 4 holes on the
ceiling following the dimensions shown in Fig. 1 for the
subsequent anchoring of the adjustable brackets.
3. Adjust the size of the brackets appropriately based on
the distance between the ceiling and the false ceiling
(Fig. 2).
4. Screw the brackets to the load-bearing ceiling using
the 4 screws supplied (Fig. 3).
5. Access the lower side of the hood and open the main
panel (Fig. 4).
6. Remove the metal filters and the central cover (Fig. 10
and Fig. 11) and bring the hood closer to its housing.
7. Electrically connect the hood and the air discharge
pipe (Fig. 5).
8. Anchor the hood using the 4 screws to the brackets
previously fixed to the ceiling (Fig. 6).
9. Reassemble the central cover and install the metal
filters before closing the main panel.
• Fixed directly on the false ceiling:
WARNING: use this type of installation ONLY and
EXCLUSIVELY when the false ceiling is able to support
the weight of the hood:
MOD. LINE-UP87: 25Kg. - MOD. LINE-UP117: 30Kg.
For this method of installation, use the special brackets
(Fig.7).
Perform the following steps in order:
1. Assemble the 4 brackets as shown in Fig. 7 and
tighten the 4 adjusting screws leaving sufficient travel to
engage the hood in the false ceiling.
2. Remove the metal filters and the central cover (Fig. 10
and Fig. 11) and place the hood in its housing.
3. Electrically connect the hood and the air discharge
pipe.
4. With the hood positioned, adjust the adjusting screws
until the hood is well anchored (Fig. 8).
The aspirator can also, by means of the special
extension, be positioned far from the hood at a distance
not exceeding 7mt. In this case the hood can only be
used in the exhaust version.
Respect the installation methods as shown in Fig. 9 in
order to keep the fan's rotation axis horizontal.
For the electrical connection of the motor away from the
hood always use the supplied extension cord and make
the earthing connection using the yellow-green wire.
1 1