Trouble Solving P9 - DAJ XAGD9040III User Manual

18ga. 1/4" narrow crown stapler
Table of Contents

Advertisement

TROUBLE SOLVING
PROBLEMS
Air leaking near the top of
the tool or in the trigger
area.
Air leaking near the bottom
of the tool.
Tool does nothing or
operates sluggishly.
Fasteners are jammed in
the tool frequently.
POSSIBLE CAUSES
1. Loose screws.
2. Worn or damaged O-rings or seals.
1. Loose screws.
2. Worn or damaged O-rings or seals.
1. Inadequate air supply.
2. Tool is too dry.
3. Exhaust blocked.
4. Worn or damaged O-rings or seals.
1. Driver channel is worn.
2. Piston is broken or worn.
3. Bent fasteners.
4. Dirty magazine.
5. Loose magazine.
6. Wrong fasteners.
SUGGESTED SOLUTIONS
1. Tighten screws.
2. Install overhaul kit.
1. Tighten screws.
2. Install overhaul kit.
1. Make sure the air compressor is set
between 70PSI and 110PSI.
2. Add about 2-3 drops of lubrication into
the air connector.
3. Clean exhaust channel.
4. Install overhaul kit.
1. Fix the drive channel.
2. Replace the piston.
3. Remove the bent fasteners, replaced with
the right fasteners.
4. Clean magazine.
5. Tighten screws.
6. Verify that fasteners are the correct size.
9

Advertisement

Table of Contents
loading

Table of Contents