Compressor Frequency At Normal Start-Up - Fujitsu AGYG09KVCB Service Manual

Hide thumbs Also See for AGYG09KVCB:
Table of Contents

Advertisement

1-4. Compressor frequency at normal start-up

¢ Model: AOYG09KVCBN
Compressor frequency soon after starting is controlled as below.
Frequency V
Frequency IV
Frequency III
Frequency II
Frequency (rps)
Time (sec)
¢ Models: AOYG12KVCBN and AOYG14KVCBN
Compressor frequency soon after starting is controlled as below.
Frequency VI
Frequency V
Frequency IV
Frequency III
Frequency II
Frequency I
Frequency
(rps)
Time (sec)
1-4. Compressor frequency at normal start-up
Frequency I
Time 1
I
II
40
56
1
2
60
240
Time 1
Time 2
I
II
35
52
1
2
60
140
Time 2
Time 3
Time 4
III
77
3
280
Time 3
Time 4
III
IV
64
71
3
4
170
200
- (04-5) -
Time 5
IV
V
90
99
4
5
360
400
Time 5
Time 6
V
VI
89
97
5
6
350
410
1. Compressor frequency control

Advertisement

Table of Contents
loading

This manual is also suitable for:

Agyg12kvcbAgyg14kvcbAoyg09kvcbnAoyg12kvcbnAoyg14kvcbn

Table of Contents