Hazardous location/explosion proof refrigerators, freezers, & dual-temp units

Advertisement

Part number 20056, Rev 0
HAZARDOUS LOCATION/EXPLOSION PROOF REFRIGERATORS, FREEZERS,
& DUAL-TEMP UNITS - MODELS EPR-1404, EPR-1704, EPR-2004,
EPR-3004, EPF-1420, EPF-1720, EPF-2020, EPF-3020, EPRFC-30
This manual describes how to operate and care for your appliance to get the best, most efficient, performance.
Note to Customer:
This merchandise was carefully packed and thoroughly inspected before leaving our plant. Responsibility for its
safe delivery was assumed by the carrier upon acceptance of the shipment. As directed on the side of your
packing carton, claims for loss or damage sustained in transit must be made on the carrier as follows:
A.) Visible Loss, Damage, Shortage External Evidence of Loss or Damage: This type of damage must be noted on
the freight bill and acknowledged by the carrier's agent (driver) at time of delivery. Make sure you get a signed
copy. Send a written request for an inspection to the carrier.
B.) Concealed Damage: This type of damage may not be discovered until the unit is being unpacked. When
concealed damage is discovered, stop unpacking immediately and contact the carrier immediately to report
the claim and request an inspection. This should be done as soon as possible and, in any case, must be done
within 15 days or receiving the merchandise. If at all possible, do not move the item and save all packaging
material for carrier's inspection.
C.) FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN THE CARRIER REFUSING TO HONOR YOUR
COMPANY'S CLAIM. UNDER NO CIRCUMSTANCES SHOULD THE MERCHANDISE BE RETURNED TO THE
MANUFACTURER. NO RETURNS WILL BE ACCEPTED WITHOUT PRIOR AUTHORIZATION.
Horizon Scientific
125 Varnfield Drive
Summerville, SC 29483
Phone: 800-648-4041
Fax:
843-821-8051
OWNER'S INSTRUCTIONS
READ THIS BOOK!
Warranty:
Two-Year Parts and Labor
5 Years Compressor Parts
Revision Date
08/23/2012

Advertisement

loading
Need help?

Need help?

Do you have a question about the EPR-1404 and is the answer not in the manual?

Questions and answers

Summary of Contents for VWR EPR-1404

  • Page 1 Part number 20056, Rev 0 HAZARDOUS LOCATION/EXPLOSION PROOF REFRIGERATORS, FREEZERS, & DUAL-TEMP UNITS - MODELS EPR-1404, EPR-1704, EPR-2004, EPR-3004, EPF-1420, EPF-1720, EPF-2020, EPF-3020, EPRFC-30 OWNER’S INSTRUCTIONS This manual describes how to operate and care for your appliance to get the best, most efficient, performance.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS RECEIVING ......................4 INSTALLATION ......................5 OPERATION ......................7 QUICK TROUBLESHOOTING GUIDE ................ 8 MAINTENANCE AND CLEANING ................10 PRODUCT WARRANTY ..................12 BEFORE CALLING THE MANUFACTURER’S TECHNICAL SUPPORT DEPARTMENT, please have the unit’s model and serial number ready as well as the problem description.
  • Page 3 ATTENTION!! PLEASE BE SURE TO CAREFULLY READ AND FOLLOW THESE IMPORTANT SAFETY INSTRUCTIONS!! THIS EQUIPMENT IS INTENDED FOR STORAGE OF FLAMMABLE LIQUIDS AND MATERIALS CAPABLE OF PRODUCING FLAMMABLE VAPORS IN HAZARDOUS LOCATIONS, CLASS I, DIVISION II, GROUP C&D. KEEP AWAY FROM SPARKS AND OPEN FLAMES. STORING UNSEALED CONTAINERS OF CORROSIVE MATERIALS CAN CAUSE PERMANENT DAMAGE TO THIS REFRIGERATION UNIT AND WILL VOID THE WARRANTY.
  • Page 4: Receiving

    RECEIVING Your unit was built, packaged, and inspected with extreme care. We shipped it to you using carriers we trust with a proven track record of careful handling, good customer service, and on time delivery. Unfortunately, regardless of all of these efforts sometimes accidents happen and occasionally those accidents result in shipping damage.
  • Page 5: Installation

    INSTALLATION UNCRATING Move your new unit as close to the final location as possible before unpacking. Remove the wooden planks or skid. This unit requires a minimum of 4 inches of air flow space in back and 3 inches on the sides and top.
  • Page 6 SHELF INSTALLATION (FOR REFRIGERATORS ONLY) Hook shelf clips onto pilaster strips (see Illustration). Position all four shelf clips equal in distance from the floor for flat shelves. Wire shelves are oriented so that cross support bars are facing down. Place shelves on shelf clips making sure all corners are seated properly. TEMPERATURE CONTROL NOTE: All of these controls are preset at the factory to provide the desired air and product temperatures inside of the units and require no further adjustment.
  • Page 7: Operation

    OPERATION After the unit is properly installed and power is applied, it will take some time before the system is cooled down to temperature and cycling normally. You should wait 8 hours on the first startup before beginning to add product to the unit. This ensures that the unit is installed and operating properly before being put into service.
  • Page 8: Quick Troubleshooting Guide

    QUICK TROUBLESHOOTING GUIDE Check these items before calling for service PROBLEM: POSSIBLE CAUSE / SOULTIONS: • Electrical circuit is not 110-120V 60Hz. • The power cord is not plugged in. • No power at electrical outlet. Check to make sure Unit does not run breaker is not tripped or fuse is not blown.
  • Page 9 PROBLEM: POSSIBLE CAUSE / SOULTIONS: • Compressor may be overheated. Please check the room Compressor noises temp and ensure the range is within 65°F to 85°F. If the problem still exists, call for service. • Door gasket is not sealing properly. Check for debris, cracks, and items passing through door at the gasket.
  • Page 10: Maintenance And Cleaning

    MAINTENANCE AND CLEANING Freezers should be defrosted whenever ¼ to ½ inch of frost has accumulated. Use the procedures in the defrosting section starting at the bottom of this page for best results. Refrigerators require little maintenance but should be cleaned periodically to keep them running efficiently.
  • Page 11 On upright units with a defrost drain – remove the drain plug on the inside floor of the freezer by pulling straight out. To access the external drain tube on models with a base panel, first remove the two screws from the base panel.
  • Page 12: Product Warranty

    HORIZON SCIENTIFIC, INC. PRODUCT WARRANTY Horizon Scientific, Inc. warrants to the original purchaser every new Horizon Scientific, Inc. refrigerated unit, the cabinet and all parts thereof, to be free from defects in material or workmanship, when such unit is installed, used, and maintained in accordance with provided instructions, for a period of two (2) years.
  • Page 13 WARRANTY IS NOT TRANSFERABLE. This warranty is not assignable and applies only in favor of the original purchaser/user to whom delivered. Any such assignment or transfer shall void the warranties herein made and shall void all warranties, express or implied, including any warranty of merchantability or fitness for a particular purpose.